AFP-3030 Operations Manual —
P/N DOC-01-033:C 05/12/2018
13
The Main Menu
General Information
Figure 1.6 Main Menu Screen
Soft Keys
Pressing the soft keys brings the user to the screens described below.
1.6.1 Event List
If there are no events active on the fire panel, pressing the Event/Graphic Screen soft key on the Main Menu screen will display the
Graphic Screen.
Pressing the soft key to the left of the Event/Graphic Screen message on the Main Menu brings up the Event List screen if there are any
events active on the fire panel. This screen will automatically display if an off-normal event requiring acknowledgment occurs, unless
the panel is in programming mode. Fire alarm events will display even in programming mode.
Line 1 displays the type of event list currently displayed. Line 15 displays the current counts of off-normal events in five categories. The
counts include both acknowledged and unacknowledged events. Line 16 contains the current date and time.
Figure 1.7 Events Count Display Screen
Soft Keys
MORE INFO - Press this key to go to the MORE INFORMATION screen, described in Section 1.6.2 below. This button will not display
if no off-normal events exist.
Pressing an Event key shows off-normal events simultaneously by event type. The currently selected event is shown at the top, and three
are shown in the list below it. Events will be listed with unacknowledged events first in reverse chronological order (oldest events at the
top to newest events at the bottom), followed by acknowledged events in reverse chronological order.
•
Using the Next/Previous special function keys will scroll to the next/previous page of the list and replace the event at the top of the
screen with the event at the cursor’s location on the next/previous screen.
•
Using the Up/Down arrow keys will scroll the cursor through the three events below, replacing the event at the top of the screen
with the currently highlighted event. Continuing past the third event will scroll through the remaining list.
•
Pressing one of the fixed function Event keys will cause the first event of that type (e.g., supervisory, fault, etc.) to display at the
top, and subsequent events of that type to display in sequence below it. If there are no events of the type, the following screen will
be displayed:
L A K E V I E W G E N E R A L H O S P I T A L
S Y S T E M N O R M A L
1 1 : 5 8 : 4 5 A T U E J A N 2 2 , 2 0 1 9
P S I S T A T U S
R E A D S T A T U S
D I S A B L E / E N A B L E
P R O G R A M / A L T E R S T A T U S
T E S T
P R I N T E R F U N C T I O N S
H I S T O R Y
E V E N T / G R A P H I C S C R E E N
F A U L T : 3 O F 5
A C K N O W L E D G E D F A U L T
A C M P S I
P S I E X T F L T M O N I T O R
1 0 : 0 3 : 2 3 A T U E 2 2 , J A N , 2 0 1 9
A C M 0 1 P 3 0
M O R E I N F O . . .
1
F L T L 0 1 M 0 0 1
M o d u l e L 0 1 M 0 0 1
2
F L T L 0 1 M 0 0 2
M o d u l e L 0 1 M 0 0 2
3
F L T P S I E X T F L T M O N I T O R
A L M : 0
S U P : 1
F L T : 5
D I S : 0
O T H E R : 4