WASP SERIES INTEGRATED SYSTEM CONTROLS
START-UP AND OPERATION INSTRUCTIONS
The information contained in these instructions is not intended to be a complete electrical installation reference, as code
requirements vary according to geographic area. These instructions focus only on the specific requirements for the Service
Pro WASP controls. They do not cover all installation aspects of the underground electrical cable and control center,
preliminary inspection, testing and service of the control center or troubleshooting. More instructions are contained in the
Bio-Kinetic Wastewater Treatment System Electrical Wiring and Control Center Installation yellow sheet. All electrical work
must be performed in accordance with the latest edition of the National Electrical Code and all applicable local codes.
PROGRAMMING THE PANEL
1. After wiring has been completed, the Service Pro WASP
control center must be programmed to operate the
Singulair system. Make sure the breakers in the home
and in the panel are both in the “on” position and the
display in the control center reads “SERVICE PRO OK”
on the top line.
2. Press the “MENU” button on the touchpad to access the
programming menu of the control center. “SET CLOCK”
and “SET HOURS” will be displayed on the screen.
Press the up or down arrow button on the touchpad to
set the correct hours value.
3. Once the correct hours value is displayed, press the
right arrow button to set the minutes value. The display
will read “SET MINUTES”. Press the up or down arrow
button to set the correct minutes value.
4. Once the correct minutes value is displayed, press the
right arrow button to set the seconds value. The display
will read “SET SECONDS”. Press the up or down arrow
button to set the correct seconds value.
5. Once the correct seconds value is displayed, press
the right arrow button on the touchpad to set the aerator
run time. The display will read “AERATOR RUN TIME”.
Press the up or down arrow button to change the aerator
run time in one minute increments. This value can be
set from 30 minutes up to continuous operation.
6. Once the aerator run time has been set, press the right
arrow button button on the touchpad to set the pump
timer mode. The display will read “PUMP TIMER
MODE”. Press the up or down arrow button to change
the timer mode. Available options include NO TIMER
mode, TIME OF DAY mode and CYCLE TIMER mode.
NO TIMER mode operates the pump on a demand
use basis controlled by the float switches. TIME OF
DAY mode enables the pump to operate at a set time
range during the day and works in conjunction with the
float switches. CYCLE TIMER mode enables pump
operation on a repeat cycle and works in conjunction
with the float switches. For TIME OF DAY mode,
proceed to step 7 below. For CYCLE TIMER mode,
proceed to step 8 below.
7. If the TIME OF DAY mode has been selected, press the
right arrow button on the touchpad to set the pump on
time. This is the time of day that the pump will begin
operating.
a. “PUMP ON TIME” and “SET HOURS” will be
displayed on the screen. Press the up or down
arrow button to set the desired hours value.
b. Once the correct hours value has been set, press
the right arrow button to set the minutes value. The
display will read “SET MINUTES”. Press the up or
down arrow button to set the desired minutes value.
c. Once the correct minutes value has been set,
press the right arrow button to set the pump off
time. This is the time of day that the pump will be
disabled. “PUMP OFF TIME” and “SET HOURS”
will be displayed on the screen. Press the up or
down arrow button to set the desired hours value.
d. Once the correct hours value has been set, press
the right arrow button to set the minutes value. The
display will read “SET MINUTES”. Press the up or
down arrow button to set the desired minutes value.
e. Proceed to step 9 below.