3.

 

APPLICATION 

 

The application of LINETROLL 110Eµ 
usually requires a previous line survey so 
that the best use of it may be obtained. 
For the best economic benefit it is recom-
mended that the indicators are used: 
 

  In easily accessibly line points for easy 

monitoring of the indicator in case of 
fault, for instance near the road. It is 
advisable to take binoculars. 

 

  Before and after line points difficult to 

reach (mountains, woods, etc.) to 
quickly locate the fault. 

 

  Next to line branching points, to easily 

locate the damaged branch. 
When installing indicators at such 
points, the use of indicators in every 
branch is recommended in order to 
provide complete information in the 
event of fault. Not doing so may cause 
confusion since there may be an 
indication in a branch due to a non-
permanent fault while another branch 
without indicator may be faulty yet 
considered healthy. 

 

  Near line points with sectionalisers to 

rapidly pinpoint and isolate the fault to 
facilitate rapid reconnection the healthy 
sections. 

 
 
 
 
LINETROLL-110E

r is suitable in: 

 

  6-69kV Distribution networks 

including SWER-lines. 

 

  Radial lines. 

 

  Multiple circuit lines (Current reset 

must be used) 

 

  Solidly-earthed-neutral networks. 

 

  Compensated and impedance-earthed-

neutral networks. If indication of earth-
faults are required, the indicators 
sensitivity and the networks residual 
fault current has to be taken into 
account. 

 

  On conductors of 5-36 mm diameter.

 

 
 

with special emphasis on: 

 

  Areas with unpredictable electro-

magnetic fields caused for example by 
parallel lines, as a better suited 
complement to the three-phase fault 
indicator LINETROLL 111K. 

 
 
 

Do 

not

 use LINETROLL 110E

r on: 

 

  Ring lines or multiple fed lines. 

 
 

Summary of Contents for LineTroll 110Em

Page 1: ...LINETROLL 110E 110E r User Guide February 2010 Page 1 of 16 LineTroll 110E LineTroll 110E r User Manual...

Page 2: ...3 Transient fault 8 4 4 Fused lines 8 4 5 Multiple faults 8 4 6 Capacitive discharges 9 4 7 PROGRAMMING 10 4 7 1 Di dt sensing 10 4 7 2 Threshold sensing 10 4 7 3 Start Stop criteria 10 4 7 4 Timer re...

Page 3: ...nd the fault or in the non damaged phase s remain idle Upon detecting a fault on the line the indication by means of an intermittent LED flash 3 red LED s and 1 amber LED indication for permanent faul...

Page 4: ...itches inside the unit In order to avoid activating the indicator due to the magnetising inrush current of the line it s di dt sensor is blocked for 5 sec upon re energising of the line While the bloc...

Page 5: ...When the unit is activated approximately 4 mA are consumed giving more than 1500 hours of flashing capacity The battery is fitted with a connector for simple replacement Figure 3 Initial battery capac...

Page 6: ...cause confusion since there may be an indication in a branch due to a non permanent fault while another branch without indicator may be faulty yet considered healthy Near line points with sectionalise...

Page 7: ...the blocking time a shows the sequence when a fault occurs less than 5 sec after line has been energised No Indication If upon re energising of the line the unit is indicating due to a previous fault...

Page 8: ...e of the fault If there is one disconnection within 5 sec followed by an automatic reclosing causing a fuse operation the indication starts but will reset after 30 sec If the automatic reset is switch...

Page 9: ...rrent of all the branches downstream the indicator is added Underground cables have larger capacitance than overhead lines This has to be taken into account when an overhead line feeds an underground...

Page 10: ...e 2 Threshold setting 4 7 3 Start Stop criteria 4 Start Stop criteria 0 Current 1 Voltage Table 3 Start Stop criteria 4 7 4 Timer reset 5 6 Timer reset 0 0 2 hours 0 1 6 hours 1 0 12 hours 1 1 24 hour...

Page 11: ...st be reset This is done by short circuiting the two pads on the underside of PCB while at the same time powering the indicator by connecting the battery The indicator will now confirm with continuous...

Page 12: ...ed LT 110E 30 40 A LT 110E r 300 A Activated flashing 4 mA Battery 3 6 V 16 5Ah type KBB 11 Recommended battery replacement approx every 10 years 5 years for LT 110E r or every 1500 operational hours...

Page 13: ...tworks Locate the indicators at strategic points along the line 9 1 Before mounting Make sure the indicator is programmed see 4 7 Programming and battery connected before mounting on the line 9 2 Live...

Page 14: ...r will in addition transmit a Low Battery message Programming Open the indicator by unscrewing the top cap from the lens See Figure 17 Pull out the electronics board just as far as to enable operation...

Page 15: ...sient fault Permanent fault GREEN RED Comments The Permanent Fault indication red LED s is delayed 70 sec to verify a permanent fault Both red and green LED s will flash on permanent faults until rese...

Page 16: ...energized or not Battery monitoring A Yellow LED will start flashing 1 10 Hz when remaining capacity is less than 20 to indicate that the battery should be replaced within the next 6 months f 1 10s 2s...

Reviews: