T6-D-USER-AV100-EN
Annex Page 3
© Park Air Systems Limited 2020
Canada
The RF power density limits according to Health Canada Safety Code 6, are shown in the table below:
The general equation for Occupational level:
RF power density = 0.6455 f
0.5
W/m
2
where, f = frequency in MHz.
The general equations for General population level:
For 100 to 300 MHz, RF power density = 1.291 W/m
2
and,
for 300 to 400 MHz, RF power density = 0.02619 f
0.6834
W/m
2
where, f = frequency in MHz.
Example
The safe distance from the antenna can be predicted using the equation:
where,
R = distance to centre of radiation in metres (m)
P = average power input to antenna in Watts (example, 100 W carrier with 95% modulation = 145 W)
G = antenna gain as a ratio (example, 2 dB = 10
2/10
= 1.585)
S = power density in W/m
2
.
Based on this formula and using a 2 dBi antenna, frequency of 118.000 MHz and a measured carrier power of
100
W, for occupational workers:
The predicted safe distance from the centre of the radiation would be approximately 1.7 m.
For persons not classed as occupational workers, and including the general public:
The minimum safe distance would be 3.8 m.
Note:
Safe distances are rounded up to the nearest 0.1 m.
Correct at 27
th
February 2020
.
For United States of America, please see overleaf.
Frequency MHz
Occupational level
W/m
2
General population level
W/m
2
112.000
6.83
1.29
118.000
7.01
1.29
127.500
7.28
1.29
136.975
7.55
1.29
155.975
8.06
1.29
225.000
9.68
1.29
300.000
11.18
1.29
399.975
12.90
1.57
R =
PG
4
S
-----------
Summary of Contents for Park Air T6-AV100
Page 12: ...T6 D USER AV100 EN Page xii Park Air Systems Limited 2020 Intentionally blank ...
Page 18: ...T6 D USER AV100 EN Page 1 4 Overview Park Air Systems Limited 2020 Intentionally blank ...
Page 28: ...T6 D USER AV100 EN Page 2 10 Description Park Air Systems Limited 2020 Intentionally blank ...
Page 34: ...T6 D USER AV100 EN Page 3 6 Installation Park Air Systems Limited 2020 Intentionally blank ...
Page 47: ...T6 D USER AV100 EN Page 7 2 Specification Park Air Systems Limited 2020 Intentionally blank ...
Page 51: ...T6 D USER AV100 EN Page 9 2 Fault finding Park Air Systems Limited 2020 Intentionally blank ...