T6-D-USER-AV100-EN
Page 7-1
Specification
© Park Air Systems Limited 2020
7 Specification
7.1 Park Air T6 VHF 100 W Power Amplifier specifications
7.2 Park Air T6 VHF 100 W Power Amplifier features and benefits
Parameter
Value
Operating frequencies
112 MHz to 156 MHz
Output Power
10 to 100 W maximum in 2 W steps
Dimensions
79 mm (2U) high
430mm (full-rack) wide
440 mm deep (including connectors)
Weight
<15 kg
Waveform
AM Voice with 25 kHz and 8.3 kHz channel spacings
Interfaces
2 x RJ45 connectors
2 x N-Type connectors
Radio Pair Operation
An amplifier can be used with a pair of main/standby radios without any additional
configuration
Operating Temperature Range
-20 to +55˚C
Standards
See
.
Feature
Benefit
Environmental Impact and Efficiency
Reduced whole life costs
Efficiency increased and power
consumption decreased
Ten-year service interval and fifteen-year
service lifetime
Reduced initial and ongoing costs
Reduced environmental impact
No RoHS specified materials used
Better environmental performance
Quality of Communications
Class-leading RF performance
Excellent reverse intermodulation
performance provides a reduction in the
requirement for filtering and isolation in the
radio system
Safety
Automatic switchover to bypass mode if
amplifier fails, ensuring transmission
capability (reduced power)
Flexible features
Independent AC and DC power options
Continually monitors own environment and
performance
Enters a ‘reduced service’ state when issues
are detected
Decreases power output
Alerts operator with diagnostic information
Simplified installation, set-up and usability
Tool free installation
No tools required for cabinet installation
Intuitive user interface
Connect to the amplifier through the radios
high resolution OLED graphical display
Visual indications of amplifier activity
Context-specific soft buttons
Indicator icons
Summary of Contents for Park Air T6-AV100
Page 12: ...T6 D USER AV100 EN Page xii Park Air Systems Limited 2020 Intentionally blank ...
Page 18: ...T6 D USER AV100 EN Page 1 4 Overview Park Air Systems Limited 2020 Intentionally blank ...
Page 28: ...T6 D USER AV100 EN Page 2 10 Description Park Air Systems Limited 2020 Intentionally blank ...
Page 34: ...T6 D USER AV100 EN Page 3 6 Installation Park Air Systems Limited 2020 Intentionally blank ...
Page 47: ...T6 D USER AV100 EN Page 7 2 Specification Park Air Systems Limited 2020 Intentionally blank ...
Page 51: ...T6 D USER AV100 EN Page 9 2 Fault finding Park Air Systems Limited 2020 Intentionally blank ...