Dangerous voltage
You must be suitably qualified to terminate a mains supply to the equipment.
Dangerous voltage
You must be careful of high RF voltages on the ANTENNA connector on the rear of the amplifier. This
is indicated by the RF voltage warning symbol ( ).
Antenna radiation
The transmit antenna must be installed such that the resultant radiated field strength is below
for limits and examples. The safe distance must be calculated for each
installation.
Fan replacement
Fan replacement must be done by a skilled person.
No user serviceable parts inside the amplifier
There are no user serviceable parts inside the amplifier.
Double pole/neutral fusing
The amplifier uses a power supply which has both live
and
neutral fuses.
AC socket-outlet
The AC socket-outlet must be installed near the amplifier and must have easy access.
Earth connection
This equipment must be earthed. The earth terminal of the AC connector must be used as the safety
earth.
AC and/or DC supply
The power cables are the amplifiers disconnect devices.
AC supply fuse rating
The amplifier AC supplies must have a 6.3 Amp time-delay fuse fitted.
Summary of Contents for Park Air T6-AV100
Page 12: ...T6 D USER AV100 EN Page xii Park Air Systems Limited 2020 Intentionally blank ...
Page 18: ...T6 D USER AV100 EN Page 1 4 Overview Park Air Systems Limited 2020 Intentionally blank ...
Page 28: ...T6 D USER AV100 EN Page 2 10 Description Park Air Systems Limited 2020 Intentionally blank ...
Page 34: ...T6 D USER AV100 EN Page 3 6 Installation Park Air Systems Limited 2020 Intentionally blank ...
Page 47: ...T6 D USER AV100 EN Page 7 2 Specification Park Air Systems Limited 2020 Intentionally blank ...
Page 51: ...T6 D USER AV100 EN Page 9 2 Fault finding Park Air Systems Limited 2020 Intentionally blank ...