Connector information
© Park Air Systems Limited 2020
Connector
Connection
Characteristics
AC inputs
IEC-C16
chassis plug
Neutral
2 input supplies: 110 to 240 V AC. Frequency: 47 to 63 Hz.
No more than 450 VA while the radio transmits under any condition.
Earth
Live
Note:
The connections are shown as viewed on the rear panel of the amplifier.
The protective earthing connector (earth) must be connected.
The cable used to connect between the equipment and the user’s AC power source must be 3-core (to IEC 227) rated 250 V AC at
8
A, and have a minimum cross-sectional area of 1.0 mm
2
per core. Northrop Grumman recommends the use of polyvinyl chloride
(PVC) insulated cable. The cable must be fitted with the IEC approved equipment connector and conform to this specification:
If PVC insulated, be not lighter than ordinary polyvinyl chloride sheathed flexible cable according to IEC publication 227
(designation H05 VV-F, H05 VVH2-F). For North America the cable must be UL listed/CSA recognised
If rubber insulated, be of synthetic rubber and not lighter than ordinary tough rubber-sheathed flexible cable according to
IEC publication 245 titled ‘Rubber Insulated Cables of Rated Voltage up to and including 450/750 V’ (designation H05 RR-F).
Connector
Connection
Earth stud
M5 thread
Note:
The amplifier is attached by the earth connection to the fixing-lug in the Park Air C4 cabinet. This
must
be attached.
Failure to comply with this instruction may result in non-compliance with the EMC Directive 2014/30/EU.
Connector
Connection
Characteristics
DC inputs
Saf-D-Grid
chassis plug
Negative -ve
2 input supplies: 21 to 32 V DC.
20 A maximum.
Not connected
Pove
Note:
The connections are shown as viewed on the rear panel of the amplifier.
The DC supply input protects against reverse polarity connection.
The DC supply cable must have a minimum cross-sectional area of 2.5 mm
2
or 12 AWG per core. If PVC insulated, be not lighter
than ordinary polyvinyl chloride sheathed flexible cable according to IEC publication 227 (designation H05 VV-F, H05 VVH2-F). For
North America the cable must be UL listed/CSA recognised.
Summary of Contents for Park Air T6-AV100
Page 12: ...T6 D USER AV100 EN Page xii Park Air Systems Limited 2020 Intentionally blank ...
Page 18: ...T6 D USER AV100 EN Page 1 4 Overview Park Air Systems Limited 2020 Intentionally blank ...
Page 28: ...T6 D USER AV100 EN Page 2 10 Description Park Air Systems Limited 2020 Intentionally blank ...
Page 34: ...T6 D USER AV100 EN Page 3 6 Installation Park Air Systems Limited 2020 Intentionally blank ...
Page 47: ...T6 D USER AV100 EN Page 7 2 Specification Park Air Systems Limited 2020 Intentionally blank ...
Page 51: ...T6 D USER AV100 EN Page 9 2 Fault finding Park Air Systems Limited 2020 Intentionally blank ...