background image

 
 
1. Overview  

Thank you for selecting the

 

NSC1210D series common positive solar charge controller. The NSC1210D 

controller is a PWM charge controller with built in LCD display that adopts the most advanced digital technique. 
The multiple load control modes enable it can be widely used on solar  home  system, traffic signal, solar street 
light, solar garden lamp, etc. The features are listed below :  

 

3-stage intelligent PWM charging : Bulk, Boost/Equalize, Float  

 

Support 3 charging options : Sealed, Gel, and Flooded  

 

LCD display design, dynamically displaying device's operating data and working condition  

 

Multiple load control modes  

 

Energy statistics function  

 

Battery temperature compensation function  

 

Extensive Electronic protection  

 
2. Product Features 

 
 
 
 
 
 
 
 

LCD 

PV terminals 

MENU Button 

Battery Terminals 

Mounting hole size 

Ø

4.5 

Load Terminals 

RTS* Port 

SET Button 

*Accessory :

 Remote Temperature Sensor  

Acquisition of battery temperature for undertaking temperature compensation of control parameters, the standard 
length of the cable is 3m (length can be customized). 

The RST300R47K3.81A connects to the port (4”) on the 

controller. 

NOTE : Unplug the RST, the temperature of battery will be set to a fixed value 25ºC 


4  5  6  7 

Summary of Contents for NSC1024A

Page 1: ...play design dynamically displaying device s operating data and working condition Multiple load control modes Energy statistics function Battery temperature compensation function Extensive Electronic protection 2 Product Features 1 LCD 5 PV terminals 2 MENU Button 6 Battery Terminals 3 Mounting hole size Ø4 5 7 Load Terminals 4 RTS Port 8 SET Button Accessory Remote Temperature Sensor Acquisition o...

Page 2: ...ontroller to recognize the system voltage 3 The battery fuse should be installed as close to battery as possible The suggested distance is within 150 mm 4 The controller is a positive ground controller Any positive connection of solar load or battery can be earth grounded as required NOTE Please connect the inverter or other load that it has the large start current to the battery rather than to th...

Page 3: ...N Load OFF LOAD Load Voltage Current Load mode Browse interface NOTE 1 When no operation the interface will be automatic cycle but the follow two interfaces not be display 2 Accumulative power zero clearing Under PV power interface press SET button and hold on 5s then the value blink press SET button again to clear the value 3 Setting temperature unit Under battery temperature interface press SET ...

Page 4: ...T button and hold on 5s till the number begin flashing then press MENU button to set the parameter press SET button to confirm 1 Timer 1 2 Timer 2 100 Light ON OFF 2 n Disabled 101 Load will be on for 1 hour since sunset 201 Load will be on for 1 hour before sunrise 102 Load will be on for 2 hours since sunset 202 Load will be on for 2 hour before sunrise 103 113 Load will be on for 3 13 hours sin...

Page 5: ...tery Battery over voltage When the battery voltage reaches to the set point of Over Voltage Disconnect Voltage the controller will stop charging the battery to protect the battery from being over charged to break down Battery over Discharge When the battery voltage reaches to the set point of Low Voltage Disconnect Voltage the controller will stop discharging the battery to protect the battery fro...

Page 6: ...onal external suppression is recommended 6 Troubleshooting Faults Possible reasons Troubleshooting The LCD is off during daytime when sunshine falls on PV modules properly PV array disconnection Confirm that PV wire connections are correct and tight Wire connection is correct LED not display 1 Battery voltage is lower than 9V 2 PV voltage is less than battery voltage 1 Please check the voltage of ...

Page 7: ...ll dimension 132x84 6x39 7 mm Mounting dimension 120x56 mm Mounting hole size Ø4 5 mm Terminals 4 mm2 Net weight 0 18 kg If the controller is working under high temperature environment please derate capacity in service Battery voltage Parameters parameters is in 12v system at 25ºC please use double value in 24V Battery charging setting Sealed Gel Flooded Over Voltage Disconnect Voltage 16 0V 16 0V...

Page 8: ...n unsuitable environment 2 PV or load current voltage or power exceeding the rated value of controller 3 User disassembly or attempted repair the controller without permission 4 The controller is damaged due to natural elements such as lighting 5 The controller is damaged during transportation and shipment Any changes without prior notice Version number V1 0 Northern Sunshine Co Ltd 82 33 Soi Ratt...