7
III.) Wiring Instructions
This pressure washer is shipped without a power cord
and is intended to be hard wired into your electrical
system. The following instructions will help you to hard
wire this unit.
Electrical Requirements:
Item Number
Circuit Rating
157304 230V/30A
WARNING: Make sure to use a dedicated circuit that
includes a GFCI. Consult local electrical code for
connection requirements.
Step 1
: Using a 3/8” wrench, remove the roof and the
top of the electrical housing. (Front panel not shown for
clarity.)
Step 2
: Feed
power cord
through the strain relief nut on
the bottom of the unit into the electrical housing.
Step 3
: Locate terminal block inside the electrical
housing and attach wires (like colors should be across
from each other).
Step 4
: Clamp cord in strain relief nut (thru the bottom
of the panel) by turning nut clockwise.
Step 5
:
Re-attach the top of the electrical housing and
the roof.
POWER SUPPLY CORD
OR CONDUIT
Summary of Contents for 157304