Remote Gateway 9150 Installation and Administration Guide
Installing the Remote Gateway 9150 unit
Standard 4.0
Attaching the cables to Remote Gateway 9150 unit
Nortel recommends that you use straight-through Amphenol cables instead of
side-entry Amphenol cables, as shown in the following diagram:
Note:
The Remote Gateway 9150 Telco 1 and 2 connections provide the
opposite gender of the connections on Meridian 1 PBX IPE or Meridian 1 PBX
11 cabinet line card slots. Therefore, you must use different cables when
connecting to the Remote Gateway 9150 unit than the cables you use to connect
to Meridian 1 PBX line cards.
G101399
Telco 1
Ethernet
Telco 2
Power
Admin
Cables must be connected and routed
away from the 9150 unit at a right angle