Ethernet Routing Switch 8600 module fundamentals
Table 3
8608SXE module LEDs
Type
Label
Color, State
Meaning
Green, Blinking
The port is transmitting data.
Amber, Steady
A fault condition exists on the line or on the
attached remote device.
TX
Off
The port has not detected a fault condition.
Green, Steady
The port is linked and enabled.
Green, Blinking
The port is receiving data.
Amber, Steady
The port has either no optical signal or no
link synchronization.
Port
RX
Off
The port has a signal, but no link.
Green, Steady
The module has completed the power-on
self-test and software initialization and is
operating normally.
Amber, Steady
The module failed the power-on self-test.
Module
Online
Off
The module power is off. If the switch
power is on, the module is performing
the power-on self-test and software
initialization. A module in this state is not
yet functional.
The 8608SXE module supports up to 32 000 table entries in its forwarding
engine. The 8608SXE module does not support R or M mode.
8616GTE module
The 8616GTE module provides 16 1000BASE-T copper gigabit Ethernet
ports with 8-pin modular (RJ-45) connectors. Each port operates in 1000
Mbps full-duplex mode and supports the IEEE 802.3ae standard. You can
attain distances of up to 100 meters with CAT 5 unshielded twisted pair
(UTP) cable. The following figure shows the 8616GTE module.
Figure 8
8616GTE module
Nortel Ethernet Routing Switch 8600
Installation — Modules