7-22
Technical specifications
Optical Multiservice Edge 6130 NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Figure 7-4
E1 coaxial cable bundle specification
Hood
Hood exit
• Angled exit recommended at 100 degrees.Close proximity of connector
positions on OME6110 faceplate prevents the user of many low profile
right angle exit hoods. (See
)
Depth
60 mm maximum connector hood and cable depth from connector mating
face
Component
Metal plated plastic (100% coverage) or fully metal shielded connector
hood
Terminations
Shielded hood terminated to cable shield and to both hood mounting
screws via the cable drain wires (both mounting screws must attach to
the drain wire through Y’d arrangement, or two drain wires) and
interference contact to exposed braid at the exit of the cable from hood.
Table 7-21 (continued)
Connector specifications for right routing E1/DS1 cables
Feature
Physical specification