background image

 

Part No. 212382-A
March 2002

4401 Great America Parkway
Santa Clara, CA 95054

*212382-A*

Installation and 
Reference for 4-Output
100 Watt DC-DC 
Converter Module

Summary of Contents for OPTera Metro 1200

Page 1: ...Part No 212382 A March 2002 4401 Great America Parkway Santa Clara CA 95054 212382 A Installation and Reference for 4 Output 100 Watt DC DC Converter Module ...

Page 2: ...es the right to make changes to the products described in this document without notice Nortel Networks NA Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein USA Requirements Only Federal Communications Commission FCC Compliance Notice Radio Frequency Notice Note This equipment has been tested and found to comply with...

Page 3: ... take appropriate measures Achtung Dieses ist ein Gerät der Funkstörgrenzwertklasse A In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist Attention Ceci est un produit de Classe A Dans un environnement domestique ce produit risque de créer des interférences radioélectriques il appartiendra...

Page 4: ...or radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications Règlement sur le brouillage radioélectrique du ministère des Communications Cet appareil numérique 4 Output 100 Watt DC DC Converter Module respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règleme...

Page 5: ...orization RMA number from Nortel Networks If Nortel Networks by its sole determination is unable to repair or replace the defective product it will refund the purchase price of the product For products repaired or replaced by Nortel Networks under this warranty the warranty will continue to apply for the unexpired period of the original one 1 year warranty or for ninety 90 days following delivery ...

Page 6: ...ABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS ARE EXPRESSLY EXCLUDED NORTEL NETWORKS SHALL NOT UNDER ANY CIRCUMSTANCES BE LIABLE TO ANY PERSON FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION DAMAGES RESULTING FROM USE OR MALFUNCTION OF THE PRODUCTS LOSS OF DATA LOSS OF PROFITS OR REVENUES OR COSTS OF REPLACEMENT GOODS E...

Page 7: ... refer to Using the OPTera Metro 1200 Ethernet Service Module For information on the BayStack 10 Power Supply Unit PSU and the 200 W AC DC Power Supply Module refer to Installation and Reference for the BayStack 10 Power Supply Unit Refer to Related publications on page 19 for information on obtaining all related publications Note The converter module operates in conjunction with the Nortel Networ...

Page 8: ...g four voltages 1 5 V 2 5 V 3 3 V 5 V The maximum output of this power supply is 100 W About this guide This guide provides the following information concerning the converter module Safety and environmental guidelines next Installing the converter module on page 9 Replacing the converter module on page 12 Connecting the cable on page 13 Connecting the power supply cord on page 15 Related publicati...

Page 9: ...ive at the organization from which you purchased the equipment Use proper grounding techniques when you install the converter module You can use a foot strap and grounded mat or wear a grounded static discharge wrist strap Installing the converter module You must have a previously installed BayStack 10 PSU and 200 watt RPS to use the converter module Nortel Networks recommends rack mounting both t...

Page 10: ...op of the plate and press gently away from you to pry the plate loose Note Prior to installing the converter module make sure you are completely familiar with the requirements of the BayStack 10 PSU Review Installation and Reference for the BayStack 10 Power Supply Unit thoroughly before beginning to install the converter module Caution When you are using the screwdriver the power is ON to the sys...

Page 11: ...you remove the converter module for any reason be sure to re insert the blank plate 3 Holding the converter module by the sides slide the converter module into the OPTera Metro 1200 Ethernet Service Module using the guide rails 10560FA Redundant Power ...

Page 12: ... Replacing the converter module 1 Make certain you are properly grounded electrically See Safety and environmental guidelines on page 9 2 Disconnect the DC cable on the converter module by unscrewing the thumbscrews and gently pulling the cord out 3 Unfasten the captive screws holding the converter module to the OPTera Metro 1200 Ethernet Service Module using a screwdriver 10558FA 100 240V 47 63Hz...

Page 13: ...the OPTera Metro 1200 Ethernet Service Module 7 Line up the locking tabs on the blank plate with the receptacles in the converter module slot of the switch Press firmly and fasten the screws using a Phillips screwdriver Refer to Connecting the cable next and Connecting the power supply cord on page 15 to continue Connecting the cable Note The 48 V converter module cable used with this converter mo...

Page 14: ...dule refer to the section on installing the power supply modules in that manual Use the 5 foot connector cable that shipped with the 200 watt RPS 1 Ensure that one end of the cable is connected to the 200 watt RPS in the BayStack 10 PSU 2 Connect the other end of the cable to the converter module in the OPTera Metro 1200 Ethernet Service Module Caution Do not attempt to use any other cables to con...

Page 15: ...ands only do not use any tools Connecting the power supply cord 1 If it is not already plugged in plug the power cord into the back of the OPTera Metro 1200 Ethernet Service Module 10561FA Redundant Power 10562EA 100 240V 47 63Hz 1 5A 0 75A ...

Page 16: ...ay to turn off power to this device The power cord must always be connected in a location that can be accessed quickly and safely in case of an emergency Vorsicht Die Stromzufuhr zu diesem Gerät kann nur durch Ziehen des Netzstromkabels unterbrochen werden Die Netzsteckdose an die das Netzstromkabel angeschlossen ist muß sich stets an einem Ort befinden der bei einem Notfall schnell und einfach zu...

Page 17: ...itivo es desenchufar el cable de alimentación El cable de alimentación siempre debe estar conectado en una ubicación que permita acceder al cable de forma rápida y segura en caso de emergencia Avvertenza Estrarre il cavo di alimentazione è l unico sistema per spegnere il dispositivo Il cavo di alimentazione deve essere sempre collegato in una posizione che permetta l accesso facile e sicuro in cas...

Page 18: ...noncondensing Storage relative humidity 10 to 95 noncondensing Operating altitude up to 10 000 feet above sea level Storage altitude 1 000 to 40 000 feet above sea level MTBF 200 000 hours at 25 degrees C Electrical requirements Input voltage 36 to 60 VDC 48 V nominal Input current 4 5 A maximum at 48 VDC Inrush current Less that 45 amperes peak at 60 VDC Safety and compliance UL 1950 or NRTL CSA ...

Page 19: ...558 B Release Notes for the BayStack 10 Power Supply Unit part number 208560 B Using the OPTera Metro 1200 Ethernet Service Module part number 212510 A Using Web based Management for the OPTera Metro 1200 Ethernet Service Module part number 212513 A Installation Instructions for the OPTera Metro 1200 Ethernet Service Module part number 212511 A Reference for the OPTera Metro 1200 Ethernet Service ...

Page 20: ... for your hardware or software product Use Adobe Acrobat Reader to open the manuals and release notes search for the sections you need and print them on most standard printers Go to the Adobe Systems Web address at www adobe com to download a free copy of Acrobat Reader You can purchase selected documentation sets CDs and technical publications though the Internet at the www1 fatbrain com document...

Page 21: ...d services When you use an ERC your call is routed to a technical support person who specializes in supporting that product or service To locate an ERC for your product or service go to the www12 nortelnetworks com URL and click ERC at the bottom of the page Technical Solutions Center Telephone EMEA 33 4 92 966 968 North America 800 2LANWAN or 800 252 6926 Asia Pacific 61 2 9927 8800 China 800 810...

Page 22: ...22 ...

Reviews: