Nortel NTQA50GA Operating Instructions Download Page 1

OPERATING INSTRUCTIONS 

NTQA50GA 

 

 
Note:  These operating instructions describe the procedure for turning on and off the amplifier 
output power using signal generators.  This amplifier will be used with transmitters which have been 
or will be certified separately.  The specific transmitter instruction book should be consulted for the 
correct method to use this amplifier with transmitters. 
 

1.  The input voltage range, applied to pin A1 of the DC input connector, should be between –36VDC and 

–57 VDC.  Pin A2 and A3 of the connector  should be grounded. 

 
2.  Pin 5 of the Data I/O connector should be grounded to enable operation of the amplifier without the 

data interface.  Pins 1, 2, 11, and 12 on the Data I/O connector are connected to ground.  Operation 
with the Data I/O interface can only be performed using the transmitter software.  See the transmitter 
manual for instructions. 

 
3.  Connect the RF signal generator to the RF input port. 
 
4.  Connect the RF output port to the measurement equipment.  Make sure the measurement equipment is 

capable of handling 33 watts, or use a power attenuator or directional coupler to attenuate the signal to 
a level the equipment can handle. 

 
5.  To turn on the amplifier, first apply the DC voltage with the specified range (-48 VDC nominal). 
 
6.  Apply RF power from the signal generator.  Adjust the RF input power until the desired RF output 

power is achieved.  The amplifier’s maximum RF output power rating is 33 watts (+45.2 dBm) 

 
7.  The gain may change up to 0.5 dB as the amplifier temperature stabilizes after turn-on.  Let the 

amplifier warm up for 10-30 minutes, then re-adjust the power to compensate for the gain change. 

 
8.  The amplifier is now operational. 
 

SPECIFICATIONS 

 
Parameter 

 

 

 

Specification

 

 
Operating Frequency 

 

 

1930 to 1990 MHz 

Rated Output Power  

 

 

+45.2 dBm (33 Watts) 

Gain at Full Power  

 

 

48 +/- 1 dB 

Input Voltage Range 

 

 

-36 to –57 VDC 

Maximum DC Power Consumption   

230 Watts 

Channeling 

 

 

 

Controlled by transmitter 

Modes of Transmission 

 

 

GSM or EDGE 

Type of Modulation 

 

 

Not applicable (performed by transmitter) 

 
Occupied Bandwidth and Emissions Designators 
 

Emissions Type   

 

Amplitude 

Frequency Removed from Carrier 

 
 

GSM (300KGXW) 

 

-30 dBc   

200 kHz 

 

 

 

 

 

-33 dBc   

250 kHz 

 

 

 

 

 

-60 dBc   

400 kHz 

 

 

 

 

 

-70 dBc   

600 kHz 

 

 

 

 

 

-73 dBc   

1200 kHz 

 

 

 

 

 

-75 dBc   

1800 kHz 

 

 

 

 

 

-80 dBc   

6000 kHz 