NT5D33 and NTRB34 Line-side E1 Interface Cards
553-3001-105
Standard 5.00
June 1999
Table 38
Line-side E1 card—E1 Switch 2 (S2) dip switch settings
After the card has been installed, display the dip switch settings using the
MMI command
Display Configuration (D C).
See
“Man-Machine E1 maintenance interface software” on page 165 for details
on how to this and the rest of the available MMI commands.
Characteristic
Selection
Switch
Position
Switch
Setting
Factory
Default
E1 framing
CRC-4 Disabled
CRC-4 Enabled
1
1
ON
OFF
OFF
E1 coding
AMI
HDB3
2
2
ON
OFF
OFF
NOT USED
leave ON
leave OFF
leave OFF
3
4
5
ON
OFF
OFF
ON
OFF
OFF
Line processing on E1
link failure
On-hook
Off-hook
6
6
ON
OFF
ON
Daisy-chaining to MMI
YES
NO
7
7
ON
OFF
OFF
MMI master or slave
Master
8
ON
ON
Slave
8
OFF