Upgrading a Norstar Voice Mail system with a 270 MB hard disk drive 39
P0994576 Issue 01
Norstar Voice Mail 4.1 Software Upgrade Guide
8. Reboot the system from a Norstar telephone. For
more information, refer to
"Rebooting the NAM"
on
page 40.
9. While the system is rebooting, the monitor will go
blank. Watch the screen during the reboot. When a
small white OS/2 box appears in the top left corner,
you must immediately press
ºAlt
and
F1
at the same time. The flashing white box only
appears on the screen for 2 seconds.
Note: If you were unable to press
ºAlt
and
F1
while the white OS/2 box appeared, cycle
the power to the NAM and repeat step 9.
10. When the Recovery Choices screen appears on the
monitor, press
×
on the keyboard.
11. The monitor, keyboard and mouse are initialized and
enabled.
Note: Steps 9 and 10 are part of a first time monitor
initialization process. If the monitor,
keyboard and mouse are removed from the
NAM, only steps 1 through 8 need to be
performed to re-enable the monitor package.
Rebootºneeded