Chapter 24 – Changing pre-programmed data
Page 433 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
Removing trunk models
To remove a trunk model from the system, load LD 14 and respond to the
prompts as follows:
LD 14
REQ
OUT
TYPE
XXX M
“XXX” = the trunk type of the model that
you are removing (Examples: COT, TIE,
DID, FEX, WAT, etc.)
CUST
0
MODL
YYY
“YYY” = the model number associated
with the trunk type you are removing
(Valid range is 1-127).
Printing model information
To print information about trunk models, load LD 20 and enter the following
commands:
LD 20
REQ PRT
TYPE
TTTT M
“TTTT” = the trunk type
MODL
YYY
“YYY” = the model number. If you want to
print all of the models for this trunk type, leave
this value blank.
Summary of Contents for Meridian Meridian 1
Page 3: ...553 3121 210 Standard 3 0 January 1999 ...
Page 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Page 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Page 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Page 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Page 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Page 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Page 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Page 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Page 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...