Page 38 of 64
Attendant console operation
Lamp Field
Use this procedure to check the functionality of the Busy Lamp Field/Console
Graphics Module. Once in this menu, the dial pad is in CGM mode. When any
dial pad keys are pressed, except the pound (#) key, the keys are echoed on
the BLF/CGM Module.
1
From Diagnostics menu 1, press “5.”
2
Press keys 0 through 9and the asterisk (*) on the dial pad. Check the
CGM to see that they are echoed.
3
Press the pound (#) to exit and return to Diagnostics menu 1.
Alerter
Use this procedure to check the pitches and volume levels of the alerter and
auxiliary tone channel.
1
From Diagnostics menu 1, press “6.”
2
Follow these instructions in any order:
Press key “1” to turn the buzz and auxiliary tones ON.
Press key “2” to turn the buzz and auxiliary tones OFF.
Press key “3” to increase the pitch of the buzz and auxiliary tones.
Press key “4” to decrease the pitch of the buzz and auxiliary tones.
Press key “5” to increase the volume of the buzz and auxiliary tones.
Press key “6” to decrease the volume of the buzz and auxiliary tones.
3
Press the pound (#) to exit and return to Diagnostics menu 1.
Display
Use this procedure to check the functionality of the alphanumeric display
panel. Cycle through a number of different display patterns to check for visual
defects.
1
From Diagnostics menu 2, press “1.”
2
Press the asterisk (*) to change the display screen pattern. Continue
changing the pattern until all the patterns have been cycled through.
3
Press the pound (#) to exit and return to Diagnostics menu 1.
Summary of Contents for Meridian 1 Series
Page 2: ......
Page 8: ...Page 8 of 64 Contents 553 2201 117 Standard 10 00 January 2002 ...
Page 10: ...Page 10 of 64 About this document 553 2201 117 Standard 10 00 January 2002 ...
Page 16: ...Page 16 of 64 Introduction 553 2201 117 Standard 10 00 January 2002 ...
Page 60: ...Page 60 of 64 Attendant console operation 553 2201 117 Standard 10 00 January 2002 ...
Page 65: ......