Installation and commissioning procedures 6-13
User guide NTXXXXXX Rel 3.0 Draft October 2000
Procedure 6-3
Connecting the interface cables
Use this procedure to connect all interface cables to the ODU of the Internet
BWA System 3200 .
The interface between all user equipment and the Internet BWA System 3200
is a 100-Ohm (DS1) or 120-Ohm (E1) twisted-pair cable assembly. The
twisted-pair cable assembly provides conductors for:
•
alarm telemetry information
•
programmable alarms
•
the RS-485 communication link
•
DC power source
•
transmit and receive data lines (tributaries)
The cable has a drain wire and color-coded solid conductors of 24 AWG. The
bundled pairs are wrapped in a foil shield with internal drain wire and covered
with a wire braid and insulating jacket. The outer braid and drain wire
terminate at pin 1.
Requirements
Before you begin this procedure:
•
Route the customer cables to an appropriate customer interface point (for
example, a cross-connect panel).
Note: For continued compliance with applicable regulatory requirements,
the DS1/E1 lines of the system cannot directly connect to a DS1/E1
network. They must connect only behind registered terminal equipment.
—continued—
DANGER
Risk of personal injury
Incorrect or unsafe installation can result in personal injury
Summary of Contents for Internet BWA System 3200
Page 6: ...vi About this document Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Page 15: ...Ordering Information 2 3 User guide NTXXXXXX Rel 3 0 Draft October 2000 ...
Page 16: ...2 4 Ordering Information Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Page 20: ...3 4 Technical specifications Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Page 40: ...5 12 User interface description Internet BWA System 3200 NTXXXXXX Rel 3 0 Draft October 2000 ...
Page 67: ......