Replacing a hard drive, tape drive, CD-ROM drive, or floppy drive
Standard 1.0
140
CallPilot
To install a new tape drive (no tape drive previously installed)
This procedure provides instructions for installing a tape drive on a server
that currently does not have a tape drive.
1
Courtesy stop CallPilot, and then power down the server.
2
Ensure that the tape drive settings are as described in “ To configure the
tape drive” on page 138.
3
Remove the side and front system covers, and place the front cover on a
flat surface.
4
Remove the slide rails for the tape drive from the side of the tape drive
bay.
Note:
If a 702t server is purchased without a tape drive, the server is
shipped with the tape drive slide rails attached to the side of the tape
drive bay inside the server.
5
Install the slide rails on the new tape drive.
6
Remove the screws and filler panel from the tape drive bay, and set them
aside.
7
Push the tab on the left side of the EMI metal shield to the right to
disengage it from the chassis, and save the shield.
8
Install the tape drive in the tape drive bay.
9
For a RAID system, refer to the diagram in “Cabling for a RAID system
with IDE CD-ROM and SCSI tape drive” on page 128 for a cabling
example. Cable the tape drive as shown in the diagram and described in
these substeps:
a.
Connect one end of the SCSI cable to the server’s wide SCSI
controller.
b.
Attach a wide SCSI terminator to the other end of the SCSI cable.
c.
Connect one of the middle connectors of the SCSI cable to the tape
drive.
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......