![Nortel CallPilot 1001rp Installation And Configuration Manual Download Page 76](http://html1.mh-extra.com/html/nortel/callpilot-1001rp/callpilot-1001rp_installation-and-configuration-manual_1707126076.webp)
Using CallPilot Manager to monitor hardware
Standard 1.0
76
CallPilot
Understanding fault management
Introduction
Fault management is a term that describes how the CallPilot server detects
and notifies you of potential or real hardware problems (faults).
The server processes events to detect hardware problems and raises alarms
to notify you when these problems occur.
Event processing
An event is any change in system configuration or operational state. An
event is also any action taken by the system that requires user notification.
Events can be as insignificant as a user logon attempt or as serious as a
faulty MPC-8 card switching to disabled status.
All events are reported to the fault management server, a subsystem within
the CallPilot server. The fault management server enables the server to listen
and respond to its clients. The interaction is called event processing and is
the means by which the server detects hardware faults.
Alarm notification
Alarms are warnings generated by events. Alarms communicate the same
information as events. However, alarms are reported in the Alarm Monitor
instead of the Event Browser, and are managed differently than events.
When an alarm appears in the Alarm Monitor, you must investigate the
problem, isolate it, and then fix the cause of the problem. When you fix the
problem, the alarm is cleared from the Alarm Monitor.
Summary of Contents for CallPilot 1001rp
Page 2: ...P0949455...
Page 6: ...vi CallPilot Publication history Standard 1 0...
Page 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Page 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Page 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Page 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Page 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Page 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Page 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Page 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Page 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Page 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Page 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Page 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Page 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Page 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Page 367: ......