October 2002
Performing RAID maintenance
Part 5: 1001rp Server Maintenance and Diagnostics
227
RAID system pack sizing
The RAID system limits the actual capacity of any system pack to the size
of the smallest drive in its pack. As drives are replaced, a mirrored set may
consist of two drives of different sizes, possibly from different
manufacturers. To support the replacement of a failed disk drive with that of
another manufacturer, an engineering restriction specifies the size of the
system pack.
To continue configuring the RAID system, calculate the drive size as
follows:
2 x smallest drive in the pack
For example, if System Pack A has a nominal capacity of 4 Gbytes (2 x 2
Gbytes), enter a system drive size of 4096. Since RAID Level 1 (mirroring)
is used, the resulting capacity is half of what you calculated.
The following tables specify the system pack sizes to enter when you
configure RAID systems. These sizes apply for currently qualified disk
drives and may change in the future.
1001rp RAID system
Qualified disk
drive make/
model
Physical drive
capacity
Size of RAID
system pack to
specify
Resulting RAID
level 1 capacity
Seagate ST34371
4096 Mbytes
8192 Mbytes
4096 Mbytes
Seagate ST34573
4096 Mbytes
8192 Mbytes
4096 Mbytes
Seagate ST39173
8192 Mbytes
16 384 Mbytes
8192 Mbytes
Seagate ST39175
8192 Mbytes
16 384 Mbytes
8192 Mbytes
Quantum
XC09J011
8192 Mbytes
16 384 Mbytes
8192 Mbytes
Summary of Contents for CallPilot 1001rp
Page 2: ...P0949455...
Page 6: ...vi CallPilot Publication history Standard 1 0...
Page 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Page 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Page 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Page 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Page 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Page 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Page 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Page 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Page 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Page 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Page 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Page 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Page 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Page 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Page 367: ......