![Nortel CallPilot 1001rp Installation And Configuration Manual Download Page 218](http://html1.mh-extra.com/html/nortel/callpilot-1001rp/callpilot-1001rp_installation-and-configuration-manual_1707126218.webp)
Performing RAID maintenance
Standard 1.0
218
CallPilot
Maintaining DAC960 RAID hard drives
Introduction
RAID hard drives must be checked for errors on a weekly basis. Errors can
be reviewed with the help of the DAC Admin Windows NT software utility
that is installed on the server.
To review errors detected on a RAID hard drive
1
Click the Start Menu.
2
Click Run.
3
Type
dacadm.exe
.
4
Click OK.
Result:
This starts the DACAdmin software utility.
5
Click the Configuration menu.
6
Choose Drive Information on the Configuration menu.
Result:
A list of all hard drives connected to the RAID controller appears.
Note:
Hard drives marked ONL are online and part of a RAID System
pack.
7
Click on a drive to see a summary of errors.
a.
If there are ten or more soft errors per day, replace the drive.
b.
Hard errors should not occur during normal operation. Contact your
Nortel Networks customer support representative if errors are
accumulating.
c.
Miscellaneous Errors are typically due to cabling or termination
problems on the SCSI bus. Verify jumper settings on all SCSI devices
and ensure that cabling is secure.
d.
When the total number of errors reaches 127, the controller marks the
drive DED. DED means offline. The drive must be replaced.
Summary of Contents for CallPilot 1001rp
Page 2: ...P0949455...
Page 6: ...vi CallPilot Publication history Standard 1 0...
Page 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Page 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Page 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Page 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Page 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Page 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Page 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Page 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Page 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Page 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Page 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Page 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Page 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Page 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Page 367: ......