![Nortel CallPilot 1001rp Installation And Configuration Manual Download Page 176](http://html1.mh-extra.com/html/nortel/callpilot-1001rp/callpilot-1001rp_installation-and-configuration-manual_1707126176.webp)
Performing RAID maintenance
Standard 1.0
176
CallPilot
To cable hard disk drives in a RAID system
1
Connect a SCSI cable to Channel 1 on the RAID card.
2
Route the cable to the expansion card area through to the left side of the
system, and down to the SCSI backplane.
Result:
The SCSI backplane provides termination for this SCSI channel.
To cable a RAID system for a tape drive
1
Connect a second SCSI cable to Channel 0 on the RAID card.
2
Route the cable between the RAID card and the right side of the system
chassis to the front of the chassis, and then down through the system to
the tape drive.
3
Attach a wide SCSI active terminator (A0766997) as the last device on
the cable.
Note:
The NTRH9034 tape drive cannot provide SCSI bus termination.
You must have an Active SCSI terminator as the last device on the SCSI
cable. Ensure that the jumper labeled TPWR is enabled on the tape
drive. The tape drive must always be connected to the second last
connector on the SCSI cable.
What’s next?
Once you have installed and cabled the RAID card, power up the server. The
card reads the configuration from the drives and configures itself. If the
server does not start properly, contact your Nortel Networks technical
support representative.
.
CAUTION
Risk of equipment damage
Ensure that no cable touches any SBC card component. Heat
transfer often causes serious damage to the system.
Summary of Contents for CallPilot 1001rp
Page 2: ...P0949455...
Page 6: ...vi CallPilot Publication history Standard 1 0...
Page 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Page 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Page 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Page 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Page 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Page 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Page 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Page 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Page 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Page 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Page 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Page 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Page 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Page 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Page 367: ......