Chapter 2 Network configuration
131
Using the Business Policy Switch 2000 Version 2.0
One client, connected to S2, responds with a host membership report. Switch S2
intercepts the report from that port, and generates a
proxy
report to its upstream
neighbor, S1. Also, two clients connected to S4 respond with host membership
reports, causing S4 to intercept the reports and to generate a
consolidated
proxy
report
to its upstream neighbor, S1.
Figure 36
Business Policy Switch filtering IP multicast streams (1 of 2)
Switch S1 treats the consolidated proxy reports from S2 and S4 as if they were
reports from any client connected to its ports, and generates a consolidated proxy
report to the designated router. In this way, the router receives a single
consolidated report from that entire subnet.
Consolidated
report
BS45022C
Host
membership
report
Host
membership
report
Designated
router
Host
membership
query
Internet
Business Policy
Switch 2000
Business Policy
Swtich 2000
Proxy
Proxy
Business Policy
Swtich 2000
S2
S4
S1
S3