MBM installation
51
Nortel Business Communications Manager 450 1.0
Installation — System
NN40160-301 01.04 Standard
July 2009
Copyright © 2006-2009 Nortel Networks
2
Choose the MBM bay (i.e.
Main 1
) that you want to configure.
3
Under Configured Device, select the type of MBM you want to install.
4
Press
Configure
.
5
Enter the
Start DN
,
Public received digits/OLI
,
Private received digits/
OLI
, and
Start Line
depending on the type of MBM.
6
Select or leave clear the
Assign target lines
check box.
7
Repeat for each media bay module you want to install.
--End--
Configuring MBMs for expansion cabinet installation
Before installing an MBM in the expansion cabinet, configure it through
Element Manager and set the DIP switches.
Procedure steps
Step
Action
1
In Element Manager, navigate to
Configuration > Resources > Telephony
Resources
.
2
Select Expansion 1 from the table. A menu appears.
3
Choose the MBM bay (i.e.
Expansion 1.1
) that you want to configure.
4
Under Configured Device, select the type of MBM you want to install.
5
Press
Configure
.
6
Enter the Start DN, Public received digits/OLI, Private received digits/OLI,
and Start Line depending on the type of MBM.
7
Select or leave clear the Assign target lines check box.
8
Locate the DIP switches at the rear or underside of the MBM.
Summary of Contents for BayStack 450 Switch
Page 141: ......