MBM installation
45
Nortel Business Communications Manager 450 1.0
Installation — System
NN40160-301 01.04 Standard
July 2009
Copyright © 2006-2009 Nortel Networks
Configuring the G4x16 or G8x16 DIP switches
Use this procedure to configure the DIP switches before you install the G4x16
or G8x16 MBM into the main unit.
Prerequisites
•
For information about lines and DNs settings for the G4x16 and G8x16
MBMs, see
G4x16 and G8x16 wiring chart (page 137)
.
Procedure steps
Step
Action
1
Locate the Module Select and Mode/Country Select DIP switches at the rear
of the G4x16 or G8x16 MBM.
2
Configure the Module Select DIP switches (on the left side at the rear of the
module) to on (up).
3
Configure the Mode/Country Select DIP switches (on the right side at the
rear of the module) to off (down).
The G4x16 and G8x16 MBMs automatically download the country profiles.
--End--
Mode/Country Select
1 2 3 4 5 6
Rear of MBM
OFF
ON
Module Select
OFF
ON
1 2 3 4 5