Troubleshooting your CallPilot system
Standard 1.06
34
CallPilot
RAID controller LED states
Refer to “Slot definition and numbering” on page 238 for the slot
position of the RAID boards in your server.
There is one red LED and a row of eight small LEDs at the back of the
RAID board.
To check if RAID board is working properly
1
The red LED comes on briefly at power up, then goes off. This
indicates that the card was accessed for detection successfully.
At the same time, all eight LEDs at the back will light.
2
Four of the eight LEDs will then go off and stay that way.
There are four LEDs lit when the RAID card is working properly.
If all eight LEDs stay on after power up and boot, the card was not
detected or is faulty.