January 2007
Working with the CallPilot server BIOS
703t Server Maintenance and Diagnostics
227
To recover from a corrupted BIOS
Notes:
To start the server into recovery mode, a memory DIMM module
must be installed in the first socket, and a floppy disk drive must be
installed.
The CMOS is not cleared when the system BIOS is updated.
1
Insert the BIOS update disk (NTRH8057) into the floppy disk drive.
2
Power down the server.
3
Remove the server cover and access the motherboard.
4
Move the Boot jumper (J1H1) to pins 10 and 11.
To determine the jumper location, see “Jumper locations and
settings” on page 228.
Note:
The jumper connects pins 9 and 10 by default for normal
BIOS.
5
Power up the server.
Result:
The server boots from the floppy disk and the BIOS update
begins automatically. A single high-pitched beep tone announces
the start of the recovery process.
6
Wait until the BIOS update is finished.
A successful update ends with two high-pitched beep tones.
A failed update is indicated by a long series of short beep tones.
These tones indicate that some of the BIOS files may be corrupted.
Three beeps indicates that the BIOS update disk is not inserted in
the floppy disk drive or is not bootable.
7
When the BIOS update is finished, the server restarts automatically.
8
While the server is restarting, remove the BIOS update disk from
the server’s floppy disk drive.
9
While the BIOS boot initialization screen is displayed, power down
the server.
10
Move the Boot jumper (J1H1) back to pins 9 and 10.
Summary of Contents for 703t
Page 6: ...Standard 1 06 6 CallPilot...
Page 8: ...8 CallPilot Publication history Standard 1 06...
Page 12: ...Task List Standard 1 06 12 CallPilot...
Page 16: ...Contents Standard 1 06 16 CallPilot...
Page 64: ...Using Windows online diagnostic tools Standard 1 06 64 CallPilot...
Page 76: ...Using serial port diagnostic tools Standard 1 06 76 CallPilot...
Page 118: ...Using CallPilot system utilities Standard 1 06 118 CallPilot Figure 13 Legend Help tab...
Page 144: ...Replacing basic chassis components Standard 1 06 144 CallPilot...
Page 170: ...Replacing media drives Standard 1 06 170 CallPilot...
Page 188: ...RAID operations Standard 1 06 188 CallPilot...
Page 196: ...Replacing or adding voice processing boards Standard 1 06 196 CallPilot...
Page 247: ......