Replacing media drives
Standard 1.06
148
CallPilot
Hard drive description
The server is equipped with two 36 Gbyte wide SCSI hard drives, each
one inch high. The last bay must remain empty to ensure proper system
cooling.
SCSI drive cabling
The hard drive assembly package includes a standard 68-pin, 68
conductor, twisted-pair wide (16-bit) SCSI ribbon cable, with
terminator. This cable has three connectors: the first is for the terminator,
the second is for the hard drive, and the third is for connection to the
RAID card.
Hard drive configuration
Ensure that the hard drives are configured as follows (for instructions,
refer to the original equipment manufacturer documentation):
termination: Set the hard drive on each SCSI bus to provide
termination power to the bus.
active termination (Term Enable): disabled on both drives
parity checking: enabled on both drives
all other settings: factory default
.
CAUTION
Risk of equipment damage
The internal SCSI interface in this system supports only
single-ended SCSI devices. Use Nortel authorized
drives only.
ATTENTION
If there is a termination enable jumper on the drive, it
must NOT be set.
Termination must be provided by a SCSI terminator
attached at the end of the cable.
Summary of Contents for 703t
Page 6: ...Standard 1 06 6 CallPilot...
Page 8: ...8 CallPilot Publication history Standard 1 06...
Page 12: ...Task List Standard 1 06 12 CallPilot...
Page 16: ...Contents Standard 1 06 16 CallPilot...
Page 64: ...Using Windows online diagnostic tools Standard 1 06 64 CallPilot...
Page 76: ...Using serial port diagnostic tools Standard 1 06 76 CallPilot...
Page 118: ...Using CallPilot system utilities Standard 1 06 118 CallPilot Figure 13 Legend Help tab...
Page 144: ...Replacing basic chassis components Standard 1 06 144 CallPilot...
Page 170: ...Replacing media drives Standard 1 06 170 CallPilot...
Page 188: ...RAID operations Standard 1 06 188 CallPilot...
Page 196: ...Replacing or adding voice processing boards Standard 1 06 196 CallPilot...
Page 247: ......