Replacing basic chassis components
703t Server Maintenance and Diagnostics
141
Replacing the processor fan
Replace a malfunctioning fan with the same type as the one removed.
For more information about replacing a fan, contact your Nortel
customer service representative.
To remove the processor fan
1
Prepare the server for processor fan replacement as follows:
a.
Shut down the server, and then disconnect the power and
peripheral device cables.
b.
Place the server on its side.
c.
Remove the side cover.
d.
Remove the upper fan holder foam.
For instructions, see “Preparing the server for hardware
maintenance,” on page 120.
2
Disconnect the fan power cable connector from the server’s
motherboard.
.
CAUTION
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
.
WARNING
Risk of personal injury or equipment damage
Failure to follow the procedures in “Preparing the
server for hardware maintenance,” on page 120 can
result in electrical shock or equipment damage.
Summary of Contents for 703t
Page 6: ...Standard 1 06 6 CallPilot...
Page 8: ...8 CallPilot Publication history Standard 1 06...
Page 12: ...Task List Standard 1 06 12 CallPilot...
Page 16: ...Contents Standard 1 06 16 CallPilot...
Page 64: ...Using Windows online diagnostic tools Standard 1 06 64 CallPilot...
Page 76: ...Using serial port diagnostic tools Standard 1 06 76 CallPilot...
Page 118: ...Using CallPilot system utilities Standard 1 06 118 CallPilot Figure 13 Legend Help tab...
Page 144: ...Replacing basic chassis components Standard 1 06 144 CallPilot...
Page 170: ...Replacing media drives Standard 1 06 170 CallPilot...
Page 188: ...RAID operations Standard 1 06 188 CallPilot...
Page 196: ...Replacing or adding voice processing boards Standard 1 06 196 CallPilot...
Page 247: ......