Installing the Nortel Ethernet Routing Switch 4500 Series in an equipment rack
21
Nortel Ethernet Routing Switch on a desk or shelf
—End—
Installing the Nortel Ethernet Routing Switch 4500 Series in an
equipment rack
Before you start this procedure, ensure that the equipment rack meets
these requirements:
•
A space of 1.75 inches (4.45 centimeters) in height is available for each
switch in an EIA- or IEC-standard 19-inch (48.2-centimeter) equipment
rack.
•
The rack is bolted to the floor and braced if necessary.
•
The rack is grounded to the same grounding electrode used by the power
service in the area. The ground path must be permanent and must not
exceed 1 Ohm of resistance from the rack to the grounding electrode.
CAUTION
When you mount the device in a rack, do not stack units directly
on top of one another. You must secure each unit to the rack with
the appropriate mounting brackets. Mounting brackets cannot
support multiple units. For a translation of this statement, see
"Translations of safety messages" (page 53)
To install a 4500 Series switch in an equipment rack, perform this procedure.
Step
Action
1
Attach a bracket to each side of the switch using a #2 Phillips
screwdriver as illustrated in
"Attaching switch brackets" (page 22)
.
Nortel Ethernet Routing Switch 4500 Series
Installation Guide
NN47205-300
02.01
Standard
5.0
23 February 2007