![Nortel 1002rp Maintenance And Diagnostics Download Page 142](http://html1.mh-extra.com/html/nortel/1002rp/1002rp_maintenance-and-diagnostics_1707105142.webp)
Replacing media drives
Standard 1.11
142
CallPilot
To replace hot-pluggable SCA SCSI hard drives
1
Ensure the new hard drive has the SCSI ID set to 0, termination
disabled, and parity checking enabled.
2
Open the front bezel doors.
3
Locate the SCA SCSI drive frame below a cooling fan and beside
the media drive.
4
Loosen the two thumbscrews on the carrier of the faulty hard drive,
and remove the carrier from the chassis.
6 (far right)
1
2
A03-02 (secondary hard drive)
a. RAID pairs (logical drives) consist of the following pairs: hard drives 1
and 4, 2 and 5, and 3 and 6. These pairs are represented in the software with
the labels
A01-01
and
A01-02, A02-01
and
A02-02,
and
A03-01
and
A03-02
, where the first number is the logical drive number (for
example, A03) and the second number indicates if it is the primary or
secondary hard drive (01 for primary and 02 for secondary).
.
CAUTION
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
Hard drive bay
SCSI
channel
SCSI ID
Logical drive label
a
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......