Replacing basic chassis components
Standard 1.11
130
CallPilot
Figure 23: Fuse receptacle
5
Slide the fuse receptacle out of the fuse chamber.
Note:
Observe how the blown fuse is positioned in the receptacle.
6
Remove the blown fuse from the fuse receptacle.
7
Install the approved replacement fuse. Use a flat-blade screwdriver
to screw in the fuse receptacle with a push and 1/4 clockwise turn.
8
Slide the fuse receptacle back into its chamber.
9
Fasten the fuse receptacle with a flat-blade screwdriver.
10
Plug the power cable back into the power input socket on the
server.
11
Plug the power cable into the wall outlet.
12
Power on the server.
ATTENTION
If the fuse blows after replacement, swap one power
supply module with the other. If this does not work,
call your Nortel customer support representative.
Fuse
G101732
A
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......