IMPORTANT SAFETY INFORMATION

Safety markings are used frequently throughout this 

manual to designate a degree or level of seriousness and 

should not be ignored. 

WARNING

 indicates a potentially 

hazardous situation that if not avoided, could result in 

personal injury or death. 

CAUTION

 indicates a potentially 

hazardous situation that if not avoided, may result in minor 

or moderate injury or property damage.

 WARNING:

Improper installation, service, adjustment, or 

maintenance may cause explosion, fire, electrical 

shock or other hazardous conditions which may 

result in personal injury or property damage. 

Unless otherwise noted in these instructions, 

only factory authorized kits or accessories may 

be used with this product.

 CAUTION:

This unit uses refrigerant R-410A. DO NOT use 

any other refrigerant in this unit. Use of another 

refrigerant will damage the unit.

 WARNING:

Shut off all electrical power to the unit before 

performing any maintenance or service on the 

system. Failure to comply may result in personal 

injury or death.

 WARNING:

These units are fully charged with R-410A 

refrigerant and ready for installation. When 

a system is installed according to these 

instructions, no refrigerant charging is required. 

If repairs make it necessary for evacuation and 

charging, it should only be attempted by qualified, 

trained personnel thoroughly familiar with this 

equipment. Some local codes require licensed 

installation service personnel to service this 

type of equipment. Under no circumstances 

should the homeowner attempt to install and/or 

service this equipment. Failure to comply with 

this warning could result in equipment damage, 

personal injury, or death.

 WARNING:

Do not place combustible material on or against 

the unit cabinet. Do not place combustible 

materials, including gasoline and any other 

flammable vapors and liquids, in the vicinity of 

the unit.

 WARNING:

The safety information listed below must be 

followed during the installation, service, and 

operation of this unit. Unqualified individuals 

should not attempt to interpret these instructions 

or install this equipment. Failure to follow safety 

recommendations could result in possible 

damage to the equipment, serious personal 

injury or death.

• The installer must comply with all local codes and 

regulations which govern the installation of this type 

of equipment. Local codes and regulations take 

precedence over any recommendations contained in 

these instructions. Consult local building codes and the 

National Electrical Code (ANSI CI) for special installation 

requirements. 

•  This equipment contains liquid and gaseous refrigerant 

under high pressure. Installation or servicing should only 

be performed by qualified trained personnel thoroughly 

familiar with this type equipment.

•  All electrical wiring must be completed in accordance 

with local, state and national codes and regulations 

and with the National Electric Code (ANSI/NFPA 70) 

or in Canada the Canadian Electric Code Part 1 CSA 

C.22.1.

•  Installation of equipment may require brazing operations. 

Installer must comply with safety codes and wear 

appropriate safety equipment (safety glasses, work 

gloves, fire extinguisher, etc.) when performing brazing 

operations.

•  Install this unit only in a location and position as specified 

on 

page  6

. This unit is designed only for outdoor 

installations and should be located with consideration 

of minimizing the length of the supply and return ducts. 

Consideration should also be given to the accessibility of 

fuel, electric power, service access, noise, and shade.

•  Follow all precautions in the literature, on tags, and 

on labels provided with the equipment. Read and 

thoroughly understand the instructions provided with 

the equipment prior to performing the installation and 

operational checkout of the equipment.

INSTALLER INFORMATION

Summary of Contents for Q104SD Series

Page 1: ...mon sense plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety wa...

Page 2: ...ing an R 410A Unit in AC Mode 12 Charging an R 410A Unit in Heating Mode 12 Verification of charge in Heat Mode 12 HEAT PUMP MAINTENANCE 12 FIGURES TABLES 13 Figure 7 Q104SD Heat pump Dimensions 13 Ta...

Page 3: ...oorfan compressor andblowermotorwill all cycle on and off to maintain the indoor temperature at the desired cooling level NOTE If the temperature level is re adjusted or the system mode is reset the f...

Page 4: ...selector setting HEAT PUMP MAINTENANCE CAUTION Shut off all electrical power to the unit before performing any maintenance or service on the system Failure to comply may result in personal injury or d...

Page 5: ...asoline and any other flammable vapors and liquids in the vicinity of the unit WARNING The safety information listed below must be followed during the installation service and operation of this unit U...

Page 6: ...ng load of the area to be conditioned must be calculatedandasystemofthepropercapacityselected It is recommended that the area to be conditioned be completely insulated and vapor sealed Check the elect...

Page 7: ...beneath the unit Rigging Hoisting WARNING To avoid the risk of property damage personal injury or death it is the rigger s responsibility to ensure that whatever means are used to hoist the unit are s...

Page 8: ...ning the correct fuse or circuit breaker for the unit Incoming field wiring and minimum size of electrical conductors and circuit Units require horizontal roof curb and return air kit for horizontal i...

Page 9: ...the system when very high pressures occur during abnormal conditions Under normal conditions the switch is closed If the discharge pressure rises above 650 psig then the switch will open and de energi...

Page 10: ...seconds regardless of whether short is removed or not Qualifying conditions of minimum ambient or coil temperature do not need to be met when the unit is forced into defrost If the short across the TE...

Page 11: ...ify the unit is level and allows condensate to drain Verify the outdoor coil and top of the unit are free from obstructions and debris and all equipment access control panels are in place Verifythatth...

Page 12: ...he unit rating plate Return to the system when the outdoor temperature is 60 degrees F or higher and follow the steps defined in Charging an R410A Unit in AC Mode NOTE Unit charge MUST be verified in...

Page 13: ...2 29 5 26 0 43 0 39 3 X60K 530 29 5 26 0 43 0 39 3 FIGURES TABLES Top View 24 9 13 5 16 12 13 3 13 5 16 12 CG A 47 5 75 NPT Female Drain Connector B DOWNFLOW SUPPLY DUCT OPENING DOWNFLOW RETURN DUCT O...

Page 14: ...t Defrost Board L 24V Output Fault Monitor See thermostat manual for compatibility Brown Orange Accesory Heat Plug Indoor Thermostat Sub Base Unit Terminal Block 1 2 3 4 5 6 7 8 9 to Blower Relay Cool...

Page 15: ...See installation instructions in the branding kit 1 Couper le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la...

Page 16: ...16 Figure 10 Charging Chart for 2 Ton Units Figure 11 Charging Chart for 2 5 Ton Units Charging Charts Cooling...

Page 17: ...17 Figure 13 Charging Chart for 3 5 Ton Units Figure 12 Charging Chart for 3 Ton Units...

Page 18: ...18 Figure 14 Charging Chart for 4 Ton Units Figure 15 Charging Chart for 5 Ton Units...

Page 19: ...9 1380 22 9 1315 24 0 1215 26 0 Tap T5 1850 17 1 1795 17 6 1740 18 2 1710 18 5 1640 19 3 1595 19 8 1540 20 5 1475 21 4 X48K Tap T1 950 33 2 900 35 1 865 36 6 730 43 4 670 47 0 585 54 2 510 62 2 Tap T...

Page 20: ...VOLTS Has the thermostat been calibrated YES NO Is the thermostat level YES NO Is the heat anticipator setting correct YES NO REPLACEMENT PARTS Replacement parts are available through your distributor...

Reviews: