26

P6SP-090(C/D)a

Factory Standard: 1.5Hp Downflow Performance Chart

‡ Indicates Factory Sheave Setting

External

Unit

Static

(in-Wg)

Operating

@ 230 or

460 Volts

Adjustable Motor Sheave Setting

Fully

Closed

1/2

Turn

Open

1

Turn

Open

1.5

Turns
Open

2

Turns
Open

2.5

Turns
Open

3

Turns
Open

3.5

Turns
Open

4

Turns
Open

4.5

Turns

Open ‡

5

Turns
Open

5.5

Turns
Open

6

Turns
Open

0.1

CFM

3620

3515

3400

3285

3187

3089

RPM

893

870

847

823

803

783

kW

1.47

1.35

1.25

1.15

1.06

0.98

0.2

CFM

3590

3477

3363

3248

3132

3031

2930

RPM

918

895

872

848

825

805

785

kW

1.50

1.39

1.28

1.18

1.08

1.00

0.92

0.3

CFM

3549

3441

3331

3220

3097

2973

2864

2755

RPM

941

920

897

873

850

827

807

786

kW

1.55

1.44

1.33

1.22

1.12

1.02

0.94

0.86

0.4

CFM

3532

3419

3306

3185

3063

2932

2800

2687

2574

RPM

965

944

923

899

876

853

830

809

788

kW

1.58

1.47

1.36

1.25

1.14

1.05

0.95

0.87

0.80

0.5

CFM

3382

3267

3152

3021

2889

2750

2611

2484

2357

RPM

968

947

925

902

878

855

832

811

790

kW

1.50

1.39

1.28

1.17

1.07

0.97

0.87

0.80

0.72

0.6

CFM

3339

3239

3115

2991

2846

2700

2549

2398

2257

RPM

990

972

950

928

904

881

857

833

813

kW

1.52

1.41

1.30

1.20

1.09

0.99

0.89

0.80

0.72

0.7

CFM

3294

3184

3074

2942

2810

2652

2493

2316

RPM

1011

993

975

953

930

907

884

859

kW

1.55

1.44

1.33

1.22

1.11

1.01

0.90

0.81

0.8

CFM

3136

3024

2911

2762

2613

2435

2257

RPM

1013

995

978

955

933

910

887

kW

1.45

1.35

1.24

1.13

1.03

0.92

0.81

0.9

CFM

3082

2979

2850

2720

2548

2376

RPM

1033

1016

998

980

958

935

kW

1.48

1.36

1.25

1.15

1.03

0.92

1.0

CFM

3012

2897

2789

2647

2505

2301

RPM

1054

1036

1019

1001

984

961

kW

1.48

1.38

1.26

1.15

1.04

0.93

1.1

CFM

2834

2718

2572

2407

2242

RPM

1058

1041

1024

1005

987

kW

1.36

1.27

1.16

1.05

0.93

1.2

CFM

2630

2485

2335

RPM

1061

1045

1028

kW

1.26

1.16

1.04

1.3

CFM

2405

2237

RPM

1064

1049

kW

1.14

1.04

Values includes losses for: Unit Casing, 2” Disposable (Pleated) Filters & Dry Evaporator Coil
When utilized with H5HK Heater kits, not all operational points shown may be available for use.  Refer to the H5HK Installation 
Instructions to determine the minimum airflow requirements of the applicable heater assembly.
Deduct 250 Cfm for electric heater kits

Table 7. Blower Performance for P6SP-090(C,D)a Series

(7.5 Ton Downflow Models Only)

Summary of Contents for P6SP

Page 1: ...deciding factor when installing this product and using common sense plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper...

Page 2: ...a Multi Supply 20 Figure 13 Wiring Diag 072 090 120 Series 21 Figure 14 Ladder Diag 072 090 120 Series 22 Blower Performance Tables 23 Table 4 P6SP Alt Accessory Blower Drives 23 Table 5 P6SP 072 C D...

Page 3: ...place combustible materials including gasoline and any other flammable vapors and liquids in the vicinity of the unit WARNING PROPOSITION 65 WARNING This product contains fiberglass wool a product kno...

Page 4: ...of gravity Refer to Physical Data info pages 13 18 for center of gravity locations All panels must be securely in place during rigging and hoisting Roof Curb Condensate Drain 3 Min Figure 2 Condensate...

Page 5: ...or downflow applications never drill or punch holes in unit base Leakage may occur if unit bottom pan is punctured If any brand other than a NORDYNE Roof Curb is to be used the frame support must be c...

Page 6: ...talled in accordance with all applicablelocalcodesandthestandardsoftheNational Fire Protection Association Standard for Installation of Air Conditioning Systems NFPA 90A Design the ductwork according...

Page 7: ...ircuit containing the correct fuse or circuit breaker for the unit IMPORTANT NOTE An electrical disconnect must be installed readily accessible from and located within sight of the unit See unit data...

Page 8: ...ide of the control access panel and in Figures 13 16 pages 21 22 4 Secure the subbase or thermostat to the wall using screws provided with the thermostat 5 Install the correct thermostat housing to su...

Page 9: ...sor crankcase Failure to comply may result in damage and could cause premature failure of the system This warning should be followed at initial start up and any time the powerhasbeenremovedfor12hourso...

Page 10: ...ower mode 1 On a call for fan operation the thermostat applies 24 Vac directly to the blower contactor 2 The circulating blower is energized immediately Heating mode 1 On a call for heat the thermosta...

Page 11: ...mpartment The blower compartment should be cleaned monthly during the heating and cooling seasons to remove any dirt and lint that may have accumulated in the compartment or on the blower and motor Bu...

Page 12: ...eed for Removal with Curb Knockout for Bottom Power Entry Control Wiring Entry Power Wiring Entry 115v G F C I Convenience Outlet Factory or Field installed option Wiring supplied in field Condenser C...

Page 13: ...31 8 30 1 2 775 16 1 2 419 30 1 2 775 16 1 2 419 A Corner D Corner C Corner A Corner B B 30 762 16 1 2 419 30 762 16 1 2 419 7 178 7 1 4 184 Filter Access Horizontal Duct connections for optional acc...

Page 14: ...t mounting location Rating Label 15 3 8 390 AIR AIR Optional Economizer Hoods bottom pan top View Figure 10 P6SP 072 Series Continued physical data continued Dimensions shown in inches mm 5 3 4 146 16...

Page 15: ...Access Optional Hail Guard Hood front View 43 1 2 1403 30 762 4 102 4 102 7 1 4 184 16 1 2 419 7 178 30 762 16 1 2 419 Filter Access Horz Return Air Opening Condenser Coil Horizontal Discharge Air Ope...

Page 16: ...n top View 5 3 4 146 16 1 2 419 30 1 2 775 Discharge Air Opening 7 178 7 178 Return Air Opening 16 1 2 419 30 1 2 775 Power Entry 8 3 4 222 62 1575 101 1 4 2572 condenser end Airflow Airflow Compresso...

Page 17: ...te Drain Field Wiring Electric Element Access 2 51 4 102 Recommended Unit Disconnect Location 16 1 2 30 762 419 16 1 2 7 1 4 4 102 30 762 184 419 178 7 419 16 1 2 Filter Access Coil Condenser Heat Exc...

Page 18: ...pping Weight Center of Gravity Inches mm Corner Weights Unit Height A B C D Horizontal Duct Applications Vertical Duct Applications Lbs Kg Lbs Kg A B Lbs Kg Lbs Kg Lbs Kg Lbs Kg P6SP 072 C D 845 384 9...

Page 19: ...090Ca 208 230 V Factory Std 2 ea 13 1 83 1 2 3 1 5 4 4 4 2 35 2 39 39 50 50 090Da 460 V 2 ea 6 1 41 1 2 2 1 16 7 19 20 120Ca 208 230 V Factory Std 2 ea 16 0 110 2 3 1 5 4 4 4 2 41 0 45 45 60 60 120Da...

Page 20: ...81 92 97 110 60 60 60 60 90 100 100 110 120Da 460 V 22 30 46 55 25 30 50 60 Medium High Static Drive Electrical Data 072C 208 230 V 920609 32 33 51 58 81 92 n a 50 45 60 60 90 100 n a 072D 460 V 9205...

Page 21: ...2 L3 T1 T2 T3 BLWR CON COM 5 5 S2 CCH S2 FS S2 LP S2 HP YE BR BR BR BR L1 L2 L3 T1 T2 T3 L1 L2 L3 T1 T2 T3 COMP 2 T2 T3 T1 BK BK BK BK BR BR S2 COMP CON S1 COMP CON L3 L1 L1 L2 L2 L3 L3 ECONOMIZER PLU...

Page 22: ...2 L3 GND 24V Common 24V Hot Compressor 1 T2 T3 T1 CC2 Compressor 2 T2 T1 T3 CC1 Aux Switch N C CC2 Aux Switch N C CC1 CCH1 CCH2 IBC OFC Y1 Factory Jumper CC2 CC1 LVT C 24V COM IBC Aux Switch N O Field...

Page 23: ...listed below for the high static drive kits The factory standard drive installed in these units has been set to deliver 400 Cfm ton at an External Static Pressure ESP of 0 25 0 30 in Wg Tables 5 10 sh...

Page 24: ...8 2322 2181 2040 1870 RPM 897 876 855 831 807 780 kW 0 96 0 88 0 80 0 71 0 62 0 54 0 6 CFM 2395 2255 2115 1960 1805 RPM 901 880 858 834 809 kW 0 87 0 79 0 71 0 63 0 55 0 7 CFM 2509 2362 2214 2042 1870...

Page 25: ...1 1904 RPM 836 812 788 760 731 kW 0 88 0 77 0 67 0 60 0 54 0 6 CFM 2687 2518 2349 2177 2005 RPM 885 862 838 815 791 kW 0 98 0 88 0 79 0 69 0 59 0 7 CFM 2460 2276 2092 RPM 889 865 841 kW 0 90 0 80 0 70...

Page 26: ...9 3239 3115 2991 2846 2700 2549 2398 2257 RPM 990 972 950 928 904 881 857 833 813 kW 1 52 1 41 1 30 1 20 1 09 0 99 0 89 0 80 0 72 0 7 CFM 3294 3184 3074 2942 2810 2652 2493 2316 RPM 1011 993 975 953 9...

Page 27: ...2 2919 2776 2616 2455 2282 RPM 986 966 947 928 904 879 856 833 809 kW 1 57 1 46 1 34 1 23 1 12 1 01 0 92 0 83 0 74 0 7 CFM 3360 3251 3142 3012 2881 2722 2563 2388 2212 RPM 1010 990 971 951 931 907 882...

Page 28: ...9 712 695 678 659 639 623 kW 1 51 1 39 1 27 1 17 1 08 0 99 0 91 0 81 0 5 CFM 3998 3871 3706 3540 3368 3196 3017 RPM 761 747 731 714 697 680 661 kW 1 51 1 42 1 30 1 18 1 09 0 99 0 90 0 6 CFM 4016 3903...

Page 29: ...1 RPM 743 727 711 694 676 658 640 623 kW 1 52 1 41 1 30 1 19 1 09 0 99 0 89 0 81 0 5 CFM 3969 3816 3662 3490 3318 3127 RPM 746 729 712 695 677 660 kW 1 44 1 32 1 20 1 10 0 99 0 89 0 6 CFM 3851 3719 35...

Page 30: ...over the range of operation Always reference the charts to determine the ideal amount of sub cooling for a given liquid pressure Units charged to other values will not perform at the rated unit effic...

Page 31: ...ication Notes for use Add refrigerant when below curve Remove refrigerant when above curve 180 205 230 255 280 305 330 355 380 405 430 455 480 505 530 555 580 50 55 60 65 70 75 80 85 90 95 100 105 110...

Page 32: ...______ F Temperature Rise ___________ F INSTALLATION ADDRESS CITY_________________________ STATE_________________ UNIT MODEL _________________________________________ UNIT SERIAL _____________________...

Reviews: