background image

Regulatory Information

•  Z-Wave® is a registered trademark of Sigma Designs Inc. and/or its subsidiaries.

•  Changes or modifications not expressly approved by the manufacturer could void the user’s authority to 

operate the equipment.

•  Les changements ou modifications non approuvés expressément par la partie responsable de la 

conformité pourrait annuler l’autorité de l’utilisateur à faire fonctionner l’équipement.

•  This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference and (2) this device must 
accept any interference received, including interference that may cause undesired operation.

•  Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts 

de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire 
de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le 
brouillage est susceptible d’en compromettre le fonctionnement.

Regulatory Information 

NOTICE TO USERS IN CALIFORNIA - CR COIN CELL LITHIUM BATTERY INFORMATION:

 

THIS PRODUCT CONTAINS A CR COIN CELL LITHIUM BATTERY WHICH CONTAINS

 

PERCHLORATE MATERIAL - SPECIAL HANDLING MAY APPLY - SEE 

www.dtsc.ca.gov/hazardouswaste/perchlorate

KEEP AWAY FROM SMALL CHILDREN. IF BATTERY IS SWALLOWED, PROMPTLY SEE A DOCTOR. 

DO NOT TRY TO RECHARGE THIS BATTERY. DISPOSAL OF USED BATTERIES MUST BE MADE IN

 

ACCORDANCE WITH THE WASTE RECOVERY AND RECYCLING REGULATIONS IN YOUR AREA.

   WARNING   

This operator system is equipped with an unattended 
operation feature. This door could move unexpectedly. NO 
ONE SHOULD CROSS THE PATH OF A MOVING DOOR!

   WARNING   

This system can be installed on sectional type (roll up) doors only 
per (UL-325). DO NOT INSTALL ON ONE-PIECE DOORS!

   WARNING   

The Remote Command Transceiver must be mounted in the 
garage, in sight of the garage door, where the visual and 
audible movement warning indicators can be clearly seen 
and heard.

   WARNING   

Do not install the Remote Command Transceiver on garage 
door operators manufactured prior to 1993 (models without 
an operational safety beam entrapment detection system).

Summary of Contents for ADT Pulse GD00Z-8-ADT

Page 1: ...GARAGE DOOR OPENER REMOTE COMMAND CONTROLLER with TILT SENSOR or dial Installation Instructions GD00Z 8 ADT...

Page 2: ...e si le brouillage est susceptible d en compromettre le fonctionnement Regulatory Information NOTICE TO USERS IN CALIFORNIA CR COIN CELL LITHIUM BATTERY INFORMATION THIS PRODUCT CONTAINS A CR COIN CEL...

Page 3: ...ng the Garage Door Controller 8 To reset a Garage Door Controller 8 To remove a Garage Door Controller 8 Controller Mounting 9 Mounting the Controller in the Garage 9 Controller Connections 10 Wiring...

Page 4: ...must be assigned the Node ID of the controller to which unsolicited notifications from the Controller will be sent The ADT Pulse should set this association automatically after inclusion NOTIFICATION...

Page 5: ...n of the garage door and sends the status to the Controller The Power Supply The Power Supply provides low voltage power to the Controller Package Contents Figure 2 Package Contents GD00Z 8 ADT GARAGE...

Page 6: ...tach the mounting plate 4 If the plate was removed for screw mounting snap the Tilt Sensor on to the mounting plate NOTE Be sure the arrow on the side of the Tilt Sensor points UP Tilt Sensor Installa...

Page 7: ...pressing the Include button 5 times Location of Include button is shown in Figure 2 on Page 3 A quick beep followed by a longer beep will indicate proper reset of the GD00Z 8 ADT To add a Garage Door...

Page 8: ...7 Press and hold the Garage Door Controller s include button for 1 second See page 3 Figure 2 for the location of the include button 8 Wait while the system finds the GD00Z 8 ADT Device NOTE Adding th...

Page 9: ...recognized the Z Wave Device Details screen opens Enter a name for the device and then click Save at the upper right 10 Click Go Back and then Close the exit Manage Devices 11 Click Close again to con...

Page 10: ...can be heard Click Go Back and then Close to exit Manage Devices 6 Click Close again to confirm To remove a Garage Door Controller 1 In the web portal click the System tab 2 Click Manage Devices The M...

Page 11: ...onents The GD00Z 8 ADT can also be attached to the opener s hardware using the adjustable mounting bracket The optional adjustable mounting bracket fits 3 ways on the controller The bracket snaps onto...

Page 12: ...ket with the provided zip tie strap IMPORTANT Do not disconnect any wires currently connected to the Garage Door Opener Controller Connections Figure 6 Controller Mounting P U S H B U T T O N P U S H...

Page 13: ...s of the garage door System Operation Figure 7 Controller Mounting FLASH FLASH FLASH BEEP BEEP BEEP Use the ADT pulse touch screen or mobile app to control your garage door view status and add your ga...

Page 14: ...Battery Replacement When The Tilt Sensor Battery Gets Low The system will notify you when the Tilt Sensor battery gets low and needs replacing 1 Use a small screwdriver to open the Tilt Sensor case 2...

Page 15: ...he proper terminals on the garage door opener Trace the wires from the garage door opener s pushbutton wall console to the door opener This is where the GD00Z 8 ADT connection wires should be connecte...

Page 16: ...Copyright 2020 Nortek Security Control 10025370 Rev B...