5. MAINTENANCE AND INSPECTION
5. MAINTENANCE AND INSPECTION
Check the water supply device and the release often. You should avoid the condition of no
water or air entering into system, as this will influence unit's performance and reliability. You
should clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty of
clogged filter.
The area around the unit should be dry, clean and well ventilated. Clean the side heating
exchanger regularly to maintain good heat exchange as conserve energy.
The operation pressure of the refrigerant system should only be serviced by a certified
technician.
Check the power supply and cable connection often. Should the unit begin to operate
abnormally, switch it off and contact the qualified technician.
Discharge all water in the water pump and water system, so that freezing of the water in the
pump or water system does not occur. You should discharge the water at the bottom of water
pump if the unit will not be used for an extended period of time. You should check the unit
thoroughly and fill the system with water fully before using it for the first time
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating
system, the following precautions shall be complied with prior to conducting work on the
system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a
flammable gas or vapour being present while the work is being performed
General work area
All maintenance staff and others working in the local area shall be instructed on the nature of
work being carried out. Work in confined spaces shall be avoided. The area around the
workspace shall be sectioned off. Ensure that the conditions within the area have been made
safe by control of flammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work,
to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak
detection equipment being used is suitable for use with flammable refrigerants, i.e.
non-sparking, adequately sealed or intrinsically safe.
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts,
appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or
CO2 fire extinguisher adjacent to the charging area.
No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing
any pipe work that contains or has contained flammable refrigerant shall use any sources of
ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition
sources, including cigarette smoking, should be kept sufficiently far away from the site of
installation, repairing, removing and disposal, during which flammable refrigerant can
Summary of Contents for 7026965
Page 28: ...4 OPERATION AND USE Controller interface diagram and definition ...
Page 35: ...5 MAINTENANCE AND INSPECTION requirements ...
Page 45: ...Note Code 83900146 ...
Page 74: ...4 BETJENING OG BRUG Controllergrænsefladens diagram og definition ...
Page 91: ...6 SPECIFIKATION Bemærk Kode 83900146 ...
Page 120: ...4 BETRIEB UND VERWENDUNG Steuerungsschnittstellendiagramm und Definition ...
Page 137: ...Hinweis Code 83900146 ...
Page 166: ...4 FONCTIONNEMENT ET UTILISATION Schéma et définition de l interface du contrôleur ...
Page 183: ...Remarque Code 83900146 ...
Page 212: ...4 WERKING EN GEBRUIK Controller interface diagram en definitie ...
Page 229: ...Nota Code 83900146 ...
Page 257: ...4 DRIFT OCH ANVÄNDNING Controller gränssnittsschema och definition ...
Page 273: ...Notera Kod 83900146 ...