29
Table 11. High Altitude Deration - Natural Gas
NATURAL GAS
ALTITUDE ABOVE
SEA LEVEL
INPUT (BTU)
46,000
61,000
76,000
102,000
0 to 1,999 FT
49
49
49
49
ORIFICE SIZE
10.0
10.0
10.0
10.0
MANIFOLD PRESSURE
2,000 to 2,999 FT
49
49
49
49
ORIFICE SIZE
9.0
9.0
9.0
9.0
MANIFOLD PRESSURE
3,000 to 4,999 FT
49
49
49
49
ORIFICE SIZE
8.5
8.5
8.5
8.5
MANIFOLD PRESSURE
5,000 to 5,999 FT
51
51
51
51
ORIFICE SIZE
10.0
10.0
10.0
10.0
MANIFOLD PRESSURE
6,000 to 7,999 FT
51
51
51
51
ORIFICE SIZE
9.0
9.0
9.0
9.0
MANIFOLD PRESSURE
8,000 to 10,000 FT
51
51
51
51
ORIFICE SIZE
8.5
8.5
8.5
8.5
MANIFOLD PRESSURE
Table 12. High Altitude Deration - Propane Gas
PROPANE
ALTITUDE ABOVE
SEA LEVEL
INPUT (BTU)
46,000
61,000
76,000
102,000
0 to 1,999 FT
57
57
57
57
ORIFICE SIZE
10.0
10.0
10.0
10.0
MANIFOLD PRESSURE
2,000 to 2,999 FT
57
57
57
57
ORIFICE SIZE
9.0
9.0
9.0
9.0
MANIFOLD PRESSURE
3,000 to 4,999 FT
57
57
57
57
ORIFICE SIZE
8.5
8.5
8.5
8.5
MANIFOLD PRESSURE
5,000 to 5,999 FT
59
59
59
59
ORIFICE SIZE
10.0
10.0
10.0
10.0
MANIFOLD PRESSURE
6,000 to 7,999 FT
59
59
59
59
ORIFICE SIZE
9.0
9.0
9.0
9.0
MANIFOLD PRESSURE
8,000 to 10,000 FT
59
59
59
59
ORIFICE SIZE
8.5
8.5
8.5
8.5
MANIFOLD PRESSURE