Maintenance
5‐23
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Filling Valve
Available only with option
Level control
.
If material seeps out of the detection hole, the control module must be
replaced.
Replace control module
Nordson recommends keeping a supply of control modules on hand to
prevent disruptions in production.
NOTE:
Replace only when the control module is warm and the material is
soft (approx. 70 °C / 158 °F, depending on material).
ATTENTION:
System and adhesive pressurized. Relieve system pressure.
Failure to observe can result in serious burns.
1. Disconnect air supply and electrical connection.
2. Release screws M5 and extract control module from the warm filling
valve.
3. Put new control module in place and tighten screws crosswise.
4. Re‐connect air supply and electrical connection.
NOTE:
Observe voltage shown on solenoid valve ID plate.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...