background image

Type 6

3

E

2010

Gear Pump

Intended use

The gear pump may only be used with the specifications of the operating
manual.

The maximum values in the specification are essentially important. The gear
pumps must not be used beyond the conditions of the specification.
To operate above the conditions is not allowed, because it could be
dangerous.

Qualification of personnel

Operating company

The operator is eather a natural or legal person who use gear pumps.

The operating company must be assure,

S

to comply with all instructions and laws,

S

only use trained personnel for commissioning, operating, and/or
repairing the pumps.

Qualified personnel

Qualified personnel are persons because of their training, briefing or
schooling. They are introduced in appointments and working to operate with
gear pumps. Also they are introduced in preventation of accidents.

Summary of Contents for VDK-MIDI TYPE 6

Page 1: ...Cabe a de dosagem de volume VDK MIDI_Tipo 6 Instru es de opera o 111015997 002 Portuguese Nordson Deutschland GmbH D Buchholz Mendt D GERMANY...

Page 2: ...smod Porous Coat PowderGrid Powderware Prism Printplus ProBlue Pro Flo ProLink Pro Meter Pro Stream RBX Rhino Saturn Scoreguard Seal Sentry Select Charge Select Coat Select Cure Slautterback Smart Coa...

Page 3: ...va ao processamento de Hot melts PUR 3 Cabe a de dosagem de volume VDK MIDI 4 Possibilidades 4 Equipamento 4 Montagem 4 Coloca o em funcionamento 4 Dados t cnicos 5 Dados gerais 5 Dimens es 6 Pe as so...

Page 4: ...ndice II P N 7551854 E 2011 Nordson Deutschland GmbH VDK MIDI_Typo 6...

Page 5: ...o indevidamente as coberturas requeridas ou por manuten o insuficiente Por isso os respons veis pela seguran a da instala o t m de assegurar que S apenas pessoal qualificado seja encarregado de trabal...

Page 6: ...papel humidade e part culas de sujidade Recomendamos que se limpem regulamente os sistemas de fus o e aplica o Se ocorrem d vidas ou dificuldades durante o processamento rogamos lhe que nos contacte...

Page 7: ...e uma massa que n o se possa fundir S gaste completamente a massa fundida dentro de aprox 4 horas Seja como for contacte o fabricante da cola que est a utilizar e respeite as indica es feitas na respe...

Page 8: ...aptador de 45 Conforme o tipo de mangueira do lado do corpo sempre 9 16 18UNF do lado da mangueira a rosca UNF apropriada da mangueira de cola quente Se for desejado poss vel fornecer outros adaptador...

Page 9: ...o se podem excluir danos nos m dulos Indica o de seguran a O abastecimento de ar comprimido tamb m tem de estar em funcionamento em caso de paragem de emerg ncia pois em caso contr rio a cola pode sai...

Page 10: ...6 Cabe a de dosagem de volume P N 7551854 E 2011 Nordson Deutschland GmbH VDK MIDI_Typo 6 Dimens es 0 403 50 444 5 40 g6 5 50 164 2 8 6 3 6 30 6 H7 90 45 Fig 1...

Page 11: ...tiliza se um tra o quando o n mero de pe a se refere a todos os componentes representados na figura O n mero na coluna N de encomenda o n mero da encomenda da Nordson Uma s rie de tra os significa que...

Page 12: ...Deutschland GmbH VDK MIDI_Typo 6 Corpo base com componentes auxiliares 8 4 52 5 46 21 20 44 19 25 47 45 48 46 46 18 8 13 14 42 40 41 6 27 15 30 3 50 28 1 49 11 3 12 10 7 35 43 33 38 36 17 2 34 26 37 1...

Page 13: ...lvula de solen ide 1 21 7055472 Uni o roscada de enroscar 1 8 6 2 22 7530588 Uni o roscada desloc vel 1 8 2 23 7551857 Tubo Ermeto Fechado 1 24 7551858 Tubo Ermeto Aberto 1 25 Parafuso cil ndrico DIN...

Page 14: ...land GmbH VDK MIDI_Typo 6 Quantidade Descri o P N Pe a 50 984155 Contra porca 3 8 1 51 7053613 Bomba doseadora de engrenagens Tipo 6 1 52 7543848 Flange SR 25 1 53 1041354 R tula 1 INDICA O O itens ma...

Page 15: ...5 1 2 3 Fig 3 Pe a P N Descri o Quantidade 1 7546574 Isolamento superior 1 2 7551856 Isolamento esquerdo direito 2 3 7546580 Isolamento encaixe 1 4 Parafuso cil ndrico DIN 912 M4 x 8 8N 2 5 Parafuso c...

Page 16: ...acesso P N 7550020 1 2 3 4 3 4 Fig 4 Pe a P N Descri o Quantidade 1 7550024 Protec o de acesso traseira 1 2 7550022 Protec o de acesso dianteira 2 3 Anilha DIN 125 A 4 3 4 4 Parafuso cil ndrico DIN 9...

Page 17: ...2011 Nordson Deutschland GmbH VDK MIDI_Typo 6 AG 900 Z P N 7544936 1 2 Fig 5 Pe a P N Descri o Quantidade 1 1049800 M dulo AG 900 1 2 1075539 Agulha do bico 1 INDICA O O itens marcados com um s o pe...

Page 18: ...14 Cabe a de dosagem de volume P N 7551854 E 2011 Nordson Deutschland GmbH VDK MIDI_Typo 6...

Page 19: ...Gear Pump Type 6 Operating instructions English...

Page 20: ...E 2010 Gear pump Serial Type 6...

Page 21: ...ualified personnel 3 General safety instructions 4 Operation of new pumps 5 Alignment of the driving shaft and motor unit 6 Mounting of gear pumps 7 Starting up of the plant 7 Exchange of gear pumps d...

Page 22: ...Table of Contents II E 2010 Gear Pump...

Page 23: ...cteristics Gear pumps with drive units for many kinds of use in cooperation and arrange to the requirements of the customer In order to guarantee this high accuracy of delivery gear pumps have only sm...

Page 24: ...This operating manual must be complete and in good condition at all times Legal appointments liability The informations in this operating manual were at the creation up to date The gear pump is liabl...

Page 25: ...d be dangerous Qualification of personnel Operating company The operator is eather a natural or legal person who use gear pumps The operating company must be assure S to comply with all instructions a...

Page 26: ...pump specifications S Please observe when handling with pump or flushing medium or oil that greases and other chemical substances follow the the safety regulations that apply to the product concerned...

Page 27: ...ce of the spinning head are clean and plain We recommend Flatness appr 2 m Surface roughnes Ra 0 2 m Rt 1 m If the surface of the spinning head is not plain enough the pump can be distorted when screw...

Page 28: ...ed S Angular deviation of the driving shaft of 0 1 approx 1 75 mm lateral deviation per 1000 mm S Radial displacement of 0 2 0 4 mm of the driving shaft away from the centre of the drive plug or the e...

Page 29: ...e respective gear pump specification Starting up of the plant The temperature of the gear pumps must be that of the required standard operating temperature before they are put into operation The start...

Page 30: ...from the beam S Take the new pump out of the heating oven oven temperature approx 20 above the Polymere operating temperature S Prior to mounting of the new pump make sure that the pump rotates smooth...

Page 31: ...Type 6 9 E 2010 Gear Pump Alignment of pumps The alignment has to be performed at operating temperature...

Page 32: ...e to be taken out of the oven by means of suitable pliers e g by means of universal grip water pump pliers For disassembling the pumps are to be clamped into a bench vice and the single parts of the p...

Page 33: ...150 190 M16 140 140 140 250 M18 180 180 300 M20 200 200 500 M24 400 400 600 M27 600 600 800 M30 800 800 1000 Please observe 1 The drive torque indicated is valid for thread lubrication with MOS2 past...

Page 34: ...pressed packing rings should be treated very carefully when installing them so that the sealing properties are not affected due to unnecessary folding of cross section If the rings cannot be inserted...

Page 35: ...mp is not in operation for some time it should be protected against surrounding influences S Close inlet and outlet port S For protection against corrosion keep the dry and protect it by means of pres...

Page 36: ...14 Type 6 E 2010 Gear Pump...

Page 37: ...nter plate 2 S Put on hub plate 3 Pump serial numbers must be in equal direction one opon the other S Screw in the cylindrical screws 15 and tighten them crosswise Use a torque wrench and pay attentio...

Page 38: ...ff seal chamber 4 with packing 23 S Screw out cylindrical screws 15 S Take off hub plate 3 Use a suitable lever S Take off center plate 2 Use a suitable lever S Pull out driving arbor 7 with gear 9 an...

Page 39: ...ng temperature to 570 F with PTFE sealing max zul ssiger Gegendruck 300 bar admissable counter pressure 4270 psi Antrieb Welle 13 mm Pa feder DIN 6885 drive arbor 0 512 dia key acc DIN 6885 Drehrichtu...

Page 40: ...18 Type 6 E 2010 Gear Pump...

Reviews: