Setting Dispense Time, Pressure, And Vacuum
Shot size is determined by a combination of dispense time, air pressure, vacuum (to prevent dripping when
dispensing thin fluids) and tip size.
Selecting a Memory Cell
Memory cells can be selected on the Main screen as follows:
• Use the Up / Down (8 / 2) or Left / Right (4 / 6) keys to highlight the MEM field.
• Press the Enter key, enter the 3-digit cell number (000–399), and press the Enter key again.
OR
• Use the Easy Adjust buttons to increase or decrease the cell number.
NOTE:
Changing to a different memory cell will display the dispense time, pressure, vacuum and trigger settings
stored in that cell and set the regulator to those pressure and vacuum settings. Any changes to time, pressure or
vacuum while in a specific cell will automatically replace the current settings.
Dispense Modes
Timed Mode
This mode is used when the desired dispense time is known.
• Use the Up / Down (8 / 2) or Left / Right (4 / 6) keys to highlight the MEM, TIME, PRES or VAC field.
• Press the F1 key to cycle through the dispensing modes (TIMED -> STEADY -> TEACH -> TIMED) until TIMED is
displayed and the TIME field is highlighted.
• Press the Enter key to display the Time entry screen. Enter the dispense time, then press the Enter key to save.
OR
• Use the Easy Adjust buttons to increase or decrease dispense time.
Teach Mode
Teach Mode allows you to set the desired deposit size based on physical observation.
• Press the F1 key until TEACH is displayed, then press the F2 (Reset) key to set dispense time to all zeros.
• Press the foot pedal or the Cycle button until the desired deposit size is achieved, then release the pedal or
button. The elapsed dispense time will be displayed in the TIME field.
• Pressing the foot pedal or button again will add to the elapsed dispense time. To reset dispense time and start
over, press the F2 (Reset) button.
• Press the F3 key to Save the time setting.