Setting a New Password
• Highlight Set Password and press the Enter key.
• When the Password screen appears, enter the new password and
press the Enter key.
• When the Please Confirm Operation screen appears, press F1
(Yes) to save the new password or F3 (No) to keep the original
password.
Clearing a Password
• Pressing and holding the Enter and 1 keys while the Ultimus V is powering up will reset the security password.
• The Please Confirm Operation screen will appear. Pressing the YES function key will reset the password to “0000”
(all zeros). Pressing the NO function key will allow the Ultimus V to continue to power up without resetting the
password.
Alarm Options Screen
• The Alarm Input Signal is the signal that is sensed on the Alarm
Input pins of the digital I/O connector. The dispenser will not
allow any dispense cycles to occur when this signal is active. The
Alarm Input Signal is enabled when a check mark is shown in the
box next to Enable Input Alarm Signal.
• The Alarm Input Signal can trigger the Alarm Output Signal on
the Digital I/O connector. A check mark in the box next to Enable
Input Alarm Output Signal indicates the Alarm Output Signal is
enabled for Input Alarm Signals.
• The Alarm Input Signal can be latched. When an Alarm Input
occurs and it is latched, the user must reset the Input Alarm
before the dispense cycle can resume.
To reset the Input Alarm, view the main screen and use the Up /
Down (8 / 2) and Left / Right (4 / 6) keys to select the Input Alarm.
Pressing the F2 (Reset) key will reset the Input Alarm. A check mark
in the box next to Enable Input Alarm Latching indicates that the
Alarm Input Latch is enabled.