Deposit size is controlled by time, pressure and tip size.
Please follow these instructions to test each function. Use the convenient Dot Standards sheet
included in your dispensing kit.
Using Steady Mode to Dispense a Dot or Stripe or Fill a
Cavity
1.
Start with pressure set to zero.
2.
Place the syringe barrel over a piece of paper or test surface.
3.
Place the unit in “Steady” mode.
4.
Unsnap the safety clip. Depress and hold the foot pedal for the remainder of setup.
5.
While resting the tip on the paper (test surface), increase the air pressure by 0.069–0.138 bar
(1–2 psi) using the keypad until you have reached the desired fluid dispensing flow rate.
NOTE:
Always use the lowest possible pressure and the largest possible tip size. The
combination of the lowest possible output pr largest possible tip size + longest
possible dispense duration = most consistent and accurate deposits.
6.
Release the foot pedal.
7.
Retest the dispensing rate a few more times. Fine tune as required by making small changes
in pressure.
Correct angle
for consistent
deposits.
Remember
— always
bring the tip in contact
with the work surface
at the illustrated angle.
After the tip is in
position, press the foot
pedal. Release pedal
and remove tip by
lifting straight up.
Dispensing System Setup
Ultimus V High Precision Fluid Dispenser
17
www.nordsonefd.com [email protected]