4-30
Operation
4.10.6 Teaching Fiducials
A fiducial is a distinct shape or object on the workpiece. Fluidmove uses fiducials for location reference.
If your programming options are set to have one or more fiducials, Fluidmove will prompt you to teach
the target points on the workpiece. Choose images that are identical from part to part and in the same
location.
To teach fiducials:
1.
Follow the screen prompts and move the camera crosshairs to the first fiducial location.
Adjust the camera focus and lighting as necessary to obtain a clear image. See
2.
Click on
Teach
.
3.
Repeat Steps 1 and 2 for additional fiducials.
For detailed information on defining fiducials, refer to the
Fluidmove User Guide
or Online Help.
4.10.7 Loading a Fluid File
NOTE
The default fluid file is automatically attached to the program when you create a new
program. To attach a different fluid file, follow the instructions below. The fluid file is
saved with the program. Fluid file settings can be edited in the Fluid Manager. See
4.10.7.1 Setting up the Fluid Manager
To load a fluid file:
1.
In the Programming Window, select
File > Fluid Table > Load
from the menu bar.
2.
If your system is equipped with dual valves, you will be prompted to select Valve 1 or
Valve 2.
3.
Select a fluid file and click on
Open
.
4.
If necessary, repeat Step 1 through Step 4 for Valve 2.
To save a fluid file:
1.
Make the desired changes in the Fluid Manager and/or Line and Dot Parameters.
Refer to the
Fluidmove User Guide
or Online Help for detailed information.
2.
In the Fluidmove Programming Window, select
File > Fluid Table > Save
.
The file will be saved with the same name.
Fluid files can also be saved in the Fluid Manager. See
To save a fluid file with a different name:
1.
In the Fluidmove Programming Window, select
File > Fluid Table > Save As
.
2.
Enter the new name and click on
Save
.
Summary of Contents for Spectrum II S2-900 C Series
Page 2: ......
Page 36: ...1 22 Introduction 1 11 8 Rear View Open Figure 1 9A S2 900 Rear View Open 1 2 3 4...
Page 40: ......
Page 124: ......
Page 157: ...Calibration and Adjustment 5 33 Figure 5 38 Dispense Lift Table Controls...
Page 159: ...Calibration and Adjustment 5 35 Figure 5 40 Beacon Configuration Window...
Page 186: ......
Page 197: ...Troubleshooting 7 11 Figure 7 1 Scale Setup Menu Figure 7 2 Scale Error Message...
Page 200: ......
Page 215: ...Parts Replacement 8 15 Figure 8 11 Replacing a Panel Mounted Fuse...
Page 218: ......
Page 223: ...Specifications 9 5 Top View mm Back View mm Figure 9 2 S2 900 System Dimensions 2 of 2...
Page 225: ...Specifications 9 7 Top View mm Back View mm Figure 9 4 S2 9XXC System Dimensions 2 of 2...
Page 228: ...A 2 Appendix A Material Safety Information A 2 1 Multemps PS NO 2...
Page 229: ...Appendix A Material Safety Information A 3...
Page 230: ...A 4 Appendix A Material Safety Information...
Page 231: ...Appendix A Material Safety Information A 5...
Page 232: ...A 6 Appendix A Material Safety Information...
Page 233: ...Appendix A Material Safety Information A 7...
Page 235: ...Appendix A Material Safety Information A 9...
Page 236: ...A 10 Appendix A Material Safety Information...
Page 237: ...Appendix A Material Safety Information A 11...
Page 238: ...A 12 Appendix A Material Safety Information...
Page 239: ...Appendix A Material Safety Information A 13...
Page 240: ...A 14 Appendix A Material Safety Information...
Page 246: ......
Page 252: ......
Page 258: ......