Hydraulic Section Repair
C 2-12
Part 1022914G03
E
2007 Nordson Corporation
Return To Service
Install the circulation kit, if used, and connect the siphon and high-pressure
fluid hoses. Connect the air supply hose to the air motor. Refer to
Section B3, Installation
, for connections and circulation valve installation.
Flush the pump with a compatible cleaning solution and resume production.