8
MEG® II Airless Spray Guns with 10 ft Cable
© 2021 Nordson Corporation
Wire Color
Function
Black
Coil
Green/Yellow Ground
1
2
3
4
5
6
7
8
9
Black
Black
Grn/Yel
Black
Black
Grn/Yel
Figure 3 Electrical Connections
1. iTrax
®
spray controller (or NC-1
spray gun driver)
2. Customer-supplied wires
3. Customer-supplied terminal block
4. Fuse holder and 1 amp fuse
(optional, refer to note below)
5. Customer-supplied junction box
6. Lock nut
7. Seal ring
8. Meg II Gun
9. Ground cable
Nozzle and CleanSleeve
®
Cover
See Figure 2.
1.
Remove the nozzle nut (6) from the spray gun (3).
2.
Verify that the seat O-ring (4) is installed into the groove in the end of the seat.
NOTE:
An alternate PTFE O-ring kit is included with the spray gun to replace the
standard seat O-ring for certain applications.
3.
Insert a nozzle (5) into the nozzle nut (6).
4.
Thread the nozzle nut (6) onto the spray gun and tighten it securely with the optional
nozzle wrench to 10-12 ft-lb (14-16 N●m). Do not overtighten the nut.
5.
If desired, install a CleanSleeve cover over the spray gun following the specified
procedure as detailed in the
CleanSleeve Cover
instruction sheet (108747).