Temperature Offset and Power Limit Settings
Touch the
OFFSET & LIMITS
button on the Navigation screen (Figure 16).
The Temperature Offset and Power Limits screen appears. This screen can
be password-protected.
Figure 21 Temperature Offset and Power Limits Screen
Temperature Offset
Temperature offset is used to alter display temperature versus input
temperature. This is used to match temperature to a master hand-held
temperature probe, or to alter temperature output when using IR-type
sensors where emissivity needs to be adjusted for various metal types.
Touch the
TEMPERATURE OFFSET
field and use the keypad to set the
desired offset. Touch
ENT
to save your setting.
Power Limits
Power Limit Control:
Touch the
POWER LIMIT
button to toggle the limits
ON or OFF.
Maximum Power Output Limit
: This limits the maximum power output of
the dryer. The typical setting is 30% higher than the Ramp Power setting.
The factory default setting is 100%.
Touch the
MAX POWER OUTPUT LIMIT
field and use the keypad to set the
desired offset. Touch the
ENT
key to save your setting.
Minimum Power Output Limit:
This limits the maximum power output of
the dryer. The typical setting is 30% lower than the Ramp Power setting.
The factory default setting is 0%.
Touch the
MIN POWER OUTPUT LIMIT
field and use the keypad to set the
desired offset. Touch the
ENT
key to save your setting.