20
Applicators
P/N 317091G
E
2011 Nordson Corporation
EP11 / EP 12
Maintenance
WARNING:
Allow only qualified personnel to perform the following tasks.
Observe and follow the safety instructions in this document and all other
related documentation.
NOTE:
Maintenance is an important preventive measure to maintain
operating safety and to extend the service life of the unit. It should not be
neglected under any circumstances.
Relieving Pressure
WARNING:
System and material pressurized. Relieve system pressure
before disconnecting heated hoses. Failure to observe can result in serious
burns.
WARNING:
Hot! Risk of burns. Wear heat‐protective gloves.
1. Set motor speed of the unit feeding the material to 0 min
‐1
; switch off
motor(s).
2. Place a container under the nozzle(s) of the applicator.
3. Activate the solenoid valves electrically or manually. Repeat this
procedure until no more material flows out.