© 2021 Nordson Corporation
3-7
Powder Flow
Air Flow
12 mm
CONTROL MANIFOLD
1 2 3 4 5 6 7 8 9
Process Valve
10 mm
6 mm
RECLAIM PUMP ON (SOL 336)
6 mm
RECLAIM
SHUTTLE
VALVE
RECLAIM PUMP PURGE (SOL 340)
6 mm
12 mm
6 mm
VIRGIN
PUMP
PANEL
SHUTTLE
VALVE
PURGE
VALVE
PURGE
VIRGIN PUMP
PURGE (SOL342)
6 mm
12 mm
TO
AIR
DROP
RECLAIM
PURGE
VALVE
10 mm
6 mm
10 mm
RECLAIM
PUMP
PANEL
10 mm
TWIN CYCLONES
VIBRATOR MOTOR
IF USED
8 mm
16 mm
PICKUP
TUBE
VIRGIN POWDER
SOURCE
(BOX OR DRUM)
6 mm
16 mm
8 mm
RECLAIM POWDER
TRANSFER PAN FLUIDIZING
VIRGIN POWDER
8 mm
6 mm
16 mm
FEED CENTER SIEVE
BULK FEED SYSTEM (OPTIONAL)
VIRGIN
BULK FEED
PUMP
Figure 3-4 Single Reclaim Pump and Optional Virgin Powder Connections and Equipment